Please, I don't know which is better Bio rad Chemi DOC xrs+ or
Azure Biosystems™ c280 for protein and DNA gel applications !
Bio rad is best for gel documentation.
Thank you. did you hear about Azure gel documentation systems !
No, we are using Bio rad in our lab.
Bio-Rad is what we use as well, but many other brands probably work just as well.
I have been recommended the following :
Cleaver Scientific - microDoc
Biorad - GelDoc XR+
Cole-Parmer - Bio-Doc-IT
Aplegen - Omega Lum G
Vilber Lourmat - E-BOX VX2
I recommend you Biorad - GelDoc XR+ ..is easy to use and provide diversity of analysis and had a friendly agarose system
I worked with: Cleaver, it was the best for PAGE.
Kindly , I have human ASCs and BM-MSCs cell lines from ATCC. They mentioned on the website that they are cultured on mesenchymal stem cells media ! However, I have on my lab DMEM low glucose...
10 November 2018 8,909 4 View
I am confused about the difference between the three components and which is suitable for cell culture as I bought the first one and it is not written if suitable for cell culture or not...
08 September 2018 8,094 0 View
Kindly I need to coculture between neuroblastoma cell line (which I culture in DMEM low glucose medium with 10 % FBS) and other cell line that needs to be cultured in DMEM Megacell medium , So I...
07 August 2018 4,938 0 View
I am doing plasmid purification for about 20 Microgram yield , I wonder which is best Qiagen mini prep or promega ? and is the expiry date of Qiagen kit 1 year from opening the kit or the...
03 April 2018 487 3 View
How can I set ascale bar using image j soft ware for already taken images with leica inverted microscope. I have already followed the following steps: 1) Open the image using image j 2)From...
03 April 2018 6,132 0 View
I am trying to do transfection of SNU 449 hepatocellular carcinoma cells by GFP plasmids using Bio Rad micropulser electroporator ! according to its protocol it nables safe and reproducible...
02 March 2018 3,141 4 View
Kindly I need to do transfection for canecr cell lines by Crispr cas 9 from santa cruiz (downregulation and overexpression) , I wonder if cuvette 0.2 will work with it as I don't have 0.4 and the...
02 March 2018 235 2 View
I am trying to transfect SNU449 cell line by GFP plasmids using genepulserX Bio rad electroporator. I wonder if I can use .4 cm cuvette and voltage needed ! and what is the cell size of SNU449 !
02 March 2018 2,027 4 View
Hi, I have problems with running gel electrophoresis. I have tried agarose gel electrophoresis and native PAGE. I have two proteins, which have molecular weights of ~30kDa and ~180kDa and two...
03 March 2021 4,275 4 View
I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
I am on the lookout for the Enhanced Yellow Fluorescent Protein (Aequorea victoria) DNA sequence. Does anyone know where I can find it? Thank you in advance
03 March 2021 3,568 1 View
Hi, Could you help me to get the latest (2019, 2020) solar resource data for a particular site in JAPAN? PV GIS and NSRDB data are not in reach to JAPAN, I'm looking for some other database for...
03 March 2021 961 3 View
I have prepared a manuscript in IEEE Latex template, but for some purpose, I need to prepare a word file as well (detailed format is not required). Compared to two column .tex file, one column...
02 March 2021 1,830 3 View
Gel electrophoresis, RNA degradation, RNA extraction from fresh tissue
02 March 2021 5,433 5 View
I feel that the practice in teacher education in my country is below the expected performance level due to very poor management system. Hope I will learn something from your experiences.
02 March 2021 1,516 4 View
I'd like to perform single-strand conformation polymorphism (SSCP) in my thesis, however I cannot control the temperature of the vertical PAGE since we are using the conventional tanks. Is there a...
02 March 2021 9,157 1 View
I am going to have 3 different probes in my qPCR work that I am going to do. But I realized that the machine we have in the lab is a Rotor-Gene Q 2plex HRM Platform, saying it has green, yellow,...
01 March 2021 8,544 1 View
Can someone please give me some possible things that could go wrong? Here is my recipe: 0.5g Agarose 50 mL of TAE 1x 1 uL ethyl bromide. Gel was run at 100V for 1 hour. The buffer used is also TAE.
01 March 2021 9,952 3 View