Which one good buffer for pre-treatment of conjugate pad in Lateral Flow Assay:
1) Tris-acetate containing NaCl and 8% sucrose
2) Tris-HCl containing NaCl and 0.25% Triton X-100
3) Sodium borate containing PBS-Tween and 10% sucrose
Thank you!
I would like to suggest you to use borate buffer, 8%sucrose,BSA & tween. That should be fine
Hi @Snehal. When you say "Borate buffer, 8% Sucrose, BSA & Tween", do you mean this can be bought or this should be manually mixed? I am also new at this and I am also working on LFA.
@ Ma Kristine Yuzon .All chemical mixed in laboratory. Mixing is done by step wise.
I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
Actually, I am running cfd simulation for a heat exchanger which has two fluids one hot and other one is cold fluid. there is a solid domain between them, which I removed and instead I have used...
01 March 2021 9,537 2 View
I am simulating Heat Exchanger. I have tried and tested all the methods to resolve this issue from the internet like refining mesh, improving skewness and orthogonal quality ,extending outlet to...
01 March 2021 6,985 3 View
I have to amplify a gene and my primers just reached. The Tm for Forward primer is 64.2, and that of reverse primer is 65.5. Can some one suggest how to get the best annealing temperature? Thanks...
01 March 2021 360 7 View
Should I mesh the solid domain ? or should I use wall thickness? or Shell conduction? for Heat Transfer between two fluids of a Heat Exchanger. what is recommended?
01 March 2021 9,785 3 View
I have a virtual machine. My host Pc specs are not that good thats why i went for virtual servers. so basically my host pc has 8gb of ram with nvidia quadro k2200 4Gb DDR5 GPU ,processor intel...
01 March 2021 8,415 1 View
Is the period to autoclave not enough? The inoculation in a hood and flame and UV and alcohol.
27 February 2021 9,356 3 View
hello. i am junior researcher. I received a comment from a reviewer that he could not find NMR data in my submitted paper. I had included the NMR graph with explanation and formula to calculate...
27 February 2021 734 4 View
I have a sample of treated water sample & asked to obtain ammonia conc. in sample using a machine with 5-25 ppm detection range. However, upon testing with different dilution factors, all...
27 February 2021 8,483 3 View
As random sampling means that everyone in the population have an equal chance to be chosen, can it have inclusion criteria? My research participants have been chosen based on the inclusion...
26 February 2021 6,905 10 View
Hello! I want to quantify by ELISA the secreted (from platelets poor plasma) and the non-secreted (from platelet lysate) PF4 before and after TRAP stimulation. I will use the ELISA from R&D...
03 March 2021 1,499 2 View
Hello, If i am doing a buffer exchange for an antibody of 1mg/mL, does the elution lose protein in the process of buffer exchange? For example, if i flow through 500 uL of 1mg/mL sample, and...
03 March 2021 6,299 3 View
Dear all, I just saw this example in FB on the difference between laminar flow and turbulent flow. The flow from a pipe hits the sink and scattered. The flow from the pipe is characterized as...
02 March 2021 1,999 5 View
Hello! I'll do a size exclusion chromatography, but I only have an open column, and I'll perform the peptide extraction from yeast, using buffer lysis (sodium phosphate 50 mM/NaCl 30 mM/DNAse and...
01 March 2021 2,215 2 View
Hello Everyone. Currently I am working to characterize macrophages in the myocardium after ischemia-reperfusion injury in rats. Due to the low total cell number isolated from rat hearts I can...
01 March 2021 3,867 3 View
Can someone please give me some possible things that could go wrong? Here is my recipe: 0.5g Agarose 50 mL of TAE 1x 1 uL ethyl bromide. Gel was run at 100V for 1 hour. The buffer used is also TAE.
01 March 2021 9,952 3 View
I'm looking at the aggregation of my protein sample using DLS. Unfortunately, my buffer (20mM HEPES) also results in a set of peaks. These are at approximately 1 and 1000 d.nm. The lowest peak...
01 March 2021 9,015 2 View
When you use RIA, with a control the unknown sample with antibodies, you bare in mind the binding sites of the antibodies. However you still need to measure labelled antigen (radioactive) and not...
28 February 2021 2,133 3 View
I need to extract protein from fermented carbon sources for Bradford assay. Most researchers experiencing insolubility of pellet in resuspension buffer. Please assist me to select most suitable...
26 February 2021 7,129 3 View
Dear All, We are using Autodesk cfd to calculate the air flow in a single sided naturally ventilated room, where air flow depends only on buoyancy due to temperature difference between inside and...
25 February 2021 9,602 4 View