i use ampholytes with the range of 3.5 to 10.8 of pH in IEF gel. the voltage for running must be in what range of volt?
when i use 200V for 3 hours mu protein mixture were not run and after few minutes the current is 000 mA.
Clinicians need to crimp the self-expandable stents into a delivery sheath so they can deploy it at a target site. I want to know if there are any researchers out there discussing the amount and...
17 June 2024 5,279 0 View
Let’s say a clinician is using a steerable catheter and we want to see the range of velocities the clinician manipulates the steering module with. Are there any references citing this?
17 June 2024 4,289 0 View
I am working with a cable-driven parallel mechanism where the cables pass through anchoring points and connect to an end-effector manipulated by the user. In my setup, these anchoring points are...
14 May 2024 9,447 0 View
It aims at showing adequate explanation for the sake of linguistic analysis.
10 April 2024 2,805 1 View
I have done a stress-strain test and it looks like the picture attached. However, in here, I only have upper and lower plateau stresses. In Auricchio's model for the superelastic behavior of...
03 April 2024 9,575 3 View
I am working on the measurement of radial forces exerted by self-expandable cardiovascular stents. I need to know how much force can damage the intima of arterial walls? Please refer me to a...
31 March 2024 1,774 5 View
I'm welding (laser welding) a nitinol cylindrical tube to a nitinol flat surface, and I am evaluating three methods for the laser welding configuration (as depicted below): I) using a groove on...
26 March 2024 4,006 6 View
#!/bin/bash #PBS -N graphne #PBS -l select=1:ncpus=4:mem=12000mb:scratch_local=6000mb #PBS -l walltime=1:00:00 #PBS -j oe module add vasp/5.4.4 hostname cd...
11 March 2024 1,082 2 View
How can I calculate the risk of air embolism or blood leakage when using a microchannel catheter (polyimide, ID ~ 0.015") in femoral arteries, considering the pressure differences and factors like...
07 March 2024 320 0 View
there is a problem in my code and i dont know what is it ? if there is available code can you help me with it
17 December 2023 7,151 0 View
I got these smeared bands quite often lately. We typically run the gel at 140V with a 10-12% gel and do a wet transfer at 220 mA for 1.5 hr in cold room. We also noticed some dirty spots/dots (see...
10 August 2024 7,480 3 View
Dear QE-users, In the method where full MS positive mode and PRM mode are used, we always get an incorrect auxiliary gas reading (41 instead of 25). This only happens in this method; other...
06 August 2024 4,953 0 View
Hello, I suspect that a molecule I am using is causing bacteria to experience osmotic shock. What chemical properties should I look for to compare this capability with those of other substances?...
06 August 2024 977 1 View
I have been working on Red blood cell-derived extracellular vesicles as Antisense Oligonucleotide (ASO) carriers. We normally run agarose gel to quantify the loading efficiency. I used naked ASO...
06 August 2024 3,130 2 View
I am having an issue with my gel image where my PCR product is not appearing very bright on the gel. When I perform gel extraction, the A260/280 purity value is very low. I used the Qiagen gel...
05 August 2024 9,798 3 View
Hello guys! Do you have experience running a Oaxaca-Blinder decomposition on R applying person weights. How do you suggest doing it? I have a variable PERWT which gives more information on how...
04 August 2024 6,033 0 View
Hello everyone, I performed a PCR yesterday, and the results showed no bands on the gel. Of course, I probably missed some crucial steps, like adding my samples to the PCR strips themselves, for...
31 July 2024 2,406 6 View
Hello Everyone I have a question about structure for connectivity analysis on sources. My goal: preprocess and cut data into trials create headmodels, using template MRI file perform source...
30 July 2024 2,744 1 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
When I run autogrid4 it says: autogrid4: ERROR: Unknown receptor type: "Cr" -- Add parameters for it to the parameter library first! Look forward to your reply.Thank you so much!
29 July 2024 488 0 View