The buffer contains: 100mM NaCI, 0.1% Triton X-100, 300mM Sucrose, 1mM MgC2, 1mM EGTA, 10mM PIPES (pH 6.8), and 100uM PMSF
I would not use it. First, the PMSF is no longer intact. This compound rapidly degrades in water. You could add fresh PMSF to replenish it, but second, the Triton X-100 will have oxidized and could even be destructive due to reactive oxygen species.
Good morning to all, I have received an invitation to publish a paper from Noves Ricerca Group in a Q2 Journal. They have read my paper and very quickly they have accepted it for publication. It...
20 May 2024 7,407 3 View
We recently acquired a ViewSizer3000 from Horiba, and the manufacturer recommended us to use nanopure water from XZero for the NTA analyses. Do you recommend using any other brands of NW? Which...
05 May 2024 1,976 1 View
I've always struggled with concentrating and washing my proteins after purification. Often I lose almost everything in the process. I have used dialysis membranes followed by column filter...
16 April 2024 5,716 0 View
Hi everyone, I'm a PhD student at CAST, Analytical Biochemistry and Proteomics Research Unit, University, "G. d'Annunzio" of Chieti-Pescara. We currently use the Thermo Fisher Orbitrap Fusion...
10 April 2024 9,346 0 View
The old antibody has been discontinued and the currently offered are detecting a band at 62 kDa, which does not reflect the correct molecular weight (47 kDa).
17 March 2024 4,300 2 View
Dear Forum Members, I hope this message finds you well. I am currently considering the purchase of a Q-TOF LCMS-9030 Mass Spectrometer for my laboratory, and I would greatly appreciate hearing...
10 March 2024 9,081 0 View
In public life, democratic mechanisms can be misused. Fitting electoral rules to desired results is called Gerrymandering to remember a prominent politician who was an expertin such Machiavellian...
03 January 2024 2,849 0 View
Hi everyone, Does anyone have a recipe for zebrafish aCSF that might match the molar concentrations reported by companies like Harvard Apparatus or Tocris (in mM Na 150; K 3.0; Ca 1.4; Mg 0.8; P...
03 December 2023 3,919 0 View
Hi everyone, I have a question about position of a part in Abaqus, in particulary i have to place my beam element between two reference point (RP1 and RP2) to simulate a ligament between two...
11 November 2023 7,181 7 View
LAPT broth: 1.5% Bacto Peptone, 1% Bacto Tryptone, 1% yeast extract, 1% glucose and 0.1% Tween 80
07 November 2023 8,166 2 View
Require for Rietveld refinement in XRD.
08 August 2024 3,080 2 View
Does anyone tried to do nucleofection with AMAXA by Lonza with lower than recommended amount of buffer in the cuvettes (100 ul)?
07 August 2024 4,616 0 View
Currently, when I run SDS-PAGE, I don't see any bands at all, even though I used the same material just a day ago and it worked fine.... In our lab, we dilute the 10X running buffer to 1X and...
06 August 2024 5,373 2 View
Hello, I suspect that a molecule I am using is causing bacteria to experience osmotic shock. What chemical properties should I look for to compare this capability with those of other substances?...
06 August 2024 977 1 View
During low-temperature testing, new diffraction peaks that appear could be indicative of several phenomena. In one of our tests, we observed notable new peaks around 40° and 45° in a specific...
06 August 2024 726 3 View
I want to refine one XRD peak of my in-situ xrd but the background is never working good which ultimately fails the refinement. How to refine and adjust the background using GSAS-II
05 August 2024 5,291 2 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
How to calculate the molar proportions of the oxides from the XRF analyses?
02 August 2024 2,565 2 View
I fabricated Ti3C2Tx using concentrated HF 40%, I plot an XRD as attached image below.. please let to know if I obtained it or not.
02 August 2024 6,789 4 View
Is it the "elution buffer" or the "dialysis buffer"? Note: I'll be using NanoDrop OneC
01 August 2024 967 3 View