I don't have 1.5M tris HCl buffer for the resolving gel but I have 1 M tris HCl buffer with pH 8.8 will that work for SDS PAGE? do I need to change the amount added to the mix?
If the recipe includes water, you can reduce the volume of water and increase the volume of Tris buffer to get to the same final concentration.
thank you for your response, please elaborate Adam B Shapiro
Here is an example of a 10% resolving gel recipe:
H2O 4.1 ml
Acrylamide/bis (30% 37.5:1) 3.3 mL
Tris–HCl (1.5 M, pH 8.8). 2.5 mL
SDS 10%. 100 µL
N,N,N′,N′-tetramethylethylene-diamine (TEMED) 10 µL
Ammonium persulfate (APS), 10% 32 µL
The total volume is 10 mL, of which 2.5 mL is 1.5 M Tris, so the final Tris concentration is (2.5/10) x 1.5 M = 0.375 M
If you only have 1 M Tris, to make 10 mL of 0.375 M, you need 10 x (0.375/1) = 3.75 mL.
So, instead of using 2.5 mL of 1.5 M Tris and 4.1 mL of water, you can use 3.75 mL of 1 M Tris and 2.85 mL of water.
After COVID-19 it has seen that EFL learners technological affiliation has raised. In addition, in the post-COVID period learners started to engage AI technologies like ChatGPT while learning...
08 August 2024 8,964 4 View
How we can cite the papers from ResearchGate. I am trying to create citations for this article, Quantum Machine Learning Algorithms for Optimization Problems: Theory, Implementation, and...
08 August 2024 6,688 3 View
I am currently working on LncRNA; to know the lncRNA-protein interactions I want to do RNA pull down assay, so I need to design primers with T7 promoter. I need assistance in this regard.
07 August 2024 6,618 1 View
I want to refine one XRD peak of my in-situ xrd but the background is never working good which ultimately fails the refinement. How to refine and adjust the background using GSAS-II
05 August 2024 5,288 2 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,781 2 View
Hi, i would like to simulate an absorption process in Aspen Plus. I want to use the NRTL model und would like to add some individual Henry coefficients. Is that possible and how?
05 August 2024 2,331 2 View
AI tools like ChatGPT can enhance research work significantly when used responsibly and in conjunction with thorough human oversight.
05 August 2024 1,842 3 View
Have you ever seen a LC-MS/MS method uses both internal standards and external standards (in matrix matching purpose) but the concentrations of internal standards are outside the calibration curve...
05 August 2024 3,082 6 View
Hi everyone, I am working on brain slices for visualizing a protein in the soma and dendrites, using a fluorescence tag. However, I need a tool (not paid) for reconstruction of the whole neuron,...
04 August 2024 4,725 2 View
Citi BLOC Standard Basket Definitions: A standardized unit representing a fixed basket of construction materials, labor, and equipment costs priced in various cities. Purpose: To create a common...
04 August 2024 8,996 1 View
I got these smeared bands quite often lately. We typically run the gel at 140V with a 10-12% gel and do a wet transfer at 220 mA for 1.5 hr in cold room. We also noticed some dirty spots/dots (see...
10 August 2024 7,478 3 View
Does anyone tried to do nucleofection with AMAXA by Lonza with lower than recommended amount of buffer in the cuvettes (100 ul)?
07 August 2024 4,614 0 View
Currently, when I run SDS-PAGE, I don't see any bands at all, even though I used the same material just a day ago and it worked fine.... In our lab, we dilute the 10X running buffer to 1X and...
06 August 2024 5,370 2 View
Hello, I suspect that a molecule I am using is causing bacteria to experience osmotic shock. What chemical properties should I look for to compare this capability with those of other substances?...
06 August 2024 977 1 View
I have been working on Red blood cell-derived extracellular vesicles as Antisense Oligonucleotide (ASO) carriers. We normally run agarose gel to quantify the loading efficiency. I used naked ASO...
06 August 2024 3,129 2 View
I ran a SDS-page of a bacterial lysate and I want to quantify protein concentration in a specific band. I was thinking of using a standards ladder or make some standards are different...
05 August 2024 9,802 3 View
I am having an issue with my gel image where my PCR product is not appearing very bright on the gel. When I perform gel extraction, the A260/280 purity value is very low. I used the Qiagen gel...
05 August 2024 9,798 3 View
Is it the "elution buffer" or the "dialysis buffer"? Note: I'll be using NanoDrop OneC
01 August 2024 965 3 View
Hello everyone, I performed a PCR yesterday, and the results showed no bands on the gel. Of course, I probably missed some crucial steps, like adding my samples to the PCR strips themselves, for...
31 July 2024 2,404 6 View