It could be non specific amplification or contamination. If it is contamination it comes from template DNA, because in a 5 probe you got correct size. First at all check it, also I will recommend you to increase the melting temperature. If not works you should design new primer set. Good luck !!!
There is genomic DNA contamination in your cDNA. The Gabra1 primers are on exon 9-10 and there is a 1617pb long intron in between. By designing new primers you may easily overcome this problem.
For Gabra5 you have other problems. The forward primer sequence only partially fit to the target (TGGAAGCAGC) and the reverse primer does not fit at all.
I think that your big band is due to genomic DNA contamination. To avoid getting this band you should treat your extracted RNA with DNase to remove genomic contaminations (there are several ways of doing this, check commercial kits and ask if you need help)
Regarding the problem of alpha5 suggested by Mr Ayata you can sequence the PCR product to check if that is your desired product.
Also from your picture looks like you could improve PCR conditions by trying a gradient PCR.