Hello! I have done PBMC purification from buffi coat several times and have never had any problems, but now two times in a row I cannot get any layers or there are only two: plasma and all the rest. At first I thought maybe the problem is the sample, but now with different sample I still cannot separate the layers. I'll also add a picture. The protocol is as follows:

1. dilute 15 ml buffi coat in 30ml of warm PBS

2. 10 ml of warmed Ficoll into another tube

3. layer diluted buffi coat over ficoll slowly not to mix them

4. centrifuge at 400g for 35 min without break, acceleration also 0, 20C

So far after that I have always had nice layers so I can separate PBMC, but now I don't have any and we cannot figure out why. We are using swinging bucket rotor and 50 ml conical tubes.

We have tried also two different centrifuges, but still no hope.

Thanks for any advice!

Anni