Dear Friends
What should be the standard thickness of copper foil to use as anode electrode fabrication for lithium ion battery.
There are 3-4 option available such as 8, 10, 12, 15 micro?
Kindly suggest
Best Regards
Hi Everyone Since I have CR2032 coin cell for lithium ion battery, what will be the die specification in mm for Anode, Cathode and Separator ? I am bit confused. Everywhere looks different...
10 November 2019 2,428 3 View
If there is a small amount of carbon still in the sample after even annealing at 600 ℃ in an air atmosphere, how the TG/DTA characterization will be helpful to detect the carbon in the sample....
05 June 2019 6,431 2 View
I wanted to calculate the theoretical capacity of NiMnO3, which will be use as anode material for LIB. It is very hard to get it through literature. So I have calculated it like this: NiMnO3 +...
03 April 2018 4,353 4 View
If sample is mesoporous and EIS spectra (Nyquist plot) shows deformed semicircles, how it can be correlated with Li+ conducting extrinsically over different porous path ways, in addition to...
31 December 2017 3,546 1 View
Kindly help me to find out the detail discussion about interparticle pores and intrapores present in a porous nanomaterials.
31 December 2017 9,703 0 View
is it correct that mesoporous structures gives large XRD peaks in small 2 theta ranges due to the regular arrangements of porous channels and cages ? If the sample is mesoporous, but XRD peaks...
31 December 2017 9,036 5 View
We have made a 2.0 V battery with Graphite and Aluminium electrodes. When we spray water, we started getting stabilized current and LED glow. What will be the oxidation/reduction reaction on both...
03 April 2017 6,417 5 View
Any one has link to get new impact factor of the journals. Thanks
03 April 2017 7,925 0 View
(i) is the active material electrode area (half cell) affecting the capacity as well as OCV ? (ii) is the counter electrode area (lithium foil, half cell) affecting the capacity as well as OCV...
06 July 2015 2,201 14 View
If a rechargeable sodium-ion battery with good performance characteristics could be developed, it could have the advantage of using electrolyte systems of lower decomposition potential due to the...
09 October 2014 7,203 2 View
I’m trying to reproduce the acousto-optic coupling simulation in the paper Frequency–angular resolving LiDAR using chip-scale acousto-optic beam steering. LNOI(lithium niobate on insulator) is...
13 August 2024 9,795 0 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
I'm currently working on calculating the collision cross section (CCS) for various ions, and I'm facing challenges when dealing with sodiated and multiply charged ions. Most of the resources I’ve...
08 August 2024 8,329 0 View
I have been getting a low plasma and no coating while doing rf sputtering of copper doped ZnS using a power of 140 watts and at pressure of 6.5x10-3 Mb.
07 August 2024 4,526 4 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
I've attempted to use this method to synthesize copper nanoparticles. Copper nanoparticles can be synthesised using a variety of precursor materials. CuSO4, distilled water, NaOH, and EDTA are...
28 July 2024 8,027 3 View
I'm having problems with ion exchange chromatography. After applying my sample (a fluorescent protein), a preferential path inevitably forms. The matrix I use is DEAE-Sephacel. Could someone...
27 July 2024 6,605 0 View