Samples do not run
Please be clear with with problem, not able to understand.
Is it that your gel has run half way only, if so pass voltage to allow it move to the other end.
Sounds more like there is problem with casting of your gel...
I ran two gels in one unit. One of them rum properly but other do not.. i used 100V voltage
I think there would be a problem in your casting or loading. Also check the wells for leakage.
Why dont you rerun the half run gel. I feel you have applied less voltage. We generally use 200V voltage for one small unit, and it takes it about 30min to run completely.
Thanks a lot to all. i will do it again. thanks.
Please help me finding sequence of the PR(Pathogen related) genes expressed during HR (hypersensitive response) in N.tabaccum, either acidic or basic. I need all. Thanks
07 August 2015 1,838 1 View
I have SALK sequence no of a T-DNA mutant of a gene. now i want to make a genomic diagram with the position of insertion. How could I find the position of insertion. I check the SALK homepage but...
05 June 2015 8,322 5 View
05 June 2015 6,626 0 View
I isolated my plasmid (includes my insert) from GV3101 by mini prep kit but the concentration is too low. is there any other method to isolate the plasmid from GV3101?
04 May 2015 2,613 9 View
I extracted total protein from agro-infiltered N. benthamiana leaves by using following extraction buffer :- Protein Extraction Buffer- 50mM Tris/HCl pH 7.6, 100mM NaCl, 0.05% Tween20, 1mM EDTA,...
02 March 2015 5,690 6 View
I already extracted my protein directly in SDS buffer containing Bromophenol blue and also B-mercaptoethanol. After running SDS page, I am having problem with protein concentration. Is there any...
31 December 2014 6,663 12 View
Please some one suggest me a good protocol, giving high yield of ER membrane and nuclear protein (if both protein extraction in same buffer, then better) from agroinfilterated Nicotiana...
31 December 2014 172 4 View
SDS page troubleshooting.
10 November 2014 6,362 18 View
06 July 2014 8,425 3 View
I have two genes. I am isolating both of them (gel purification), then using each gene in one reaction of PCR with end primers for fusion of both genes, but each time I don't get any results for...
03 April 2014 2,585 26 View
Hi, I have problems with running gel electrophoresis. I have tried agarose gel electrophoresis and native PAGE. I have two proteins, which have molecular weights of ~30kDa and ~180kDa and two...
03 March 2021 4,275 4 View
Hello everyone. I am fairly new in protein chemistry field. I am trying to perform a protein induction hoping to purify my protein of interest using FPLC method. However, I am having trouble on...
03 March 2021 8,237 3 View
I did sds page to determine the difference in protein expression between 3 types of vaccine , but i don't have scanner or densitometer available. . so i wonder if there is a software to analyze...
02 March 2021 6,270 3 View
Gel electrophoresis, RNA degradation, RNA extraction from fresh tissue
02 March 2021 5,433 5 View
I'd like to perform single-strand conformation polymorphism (SSCP) in my thesis, however I cannot control the temperature of the vertical PAGE since we are using the conventional tanks. Is there a...
02 March 2021 9,157 1 View
Can someone please give me some possible things that could go wrong? Here is my recipe: 0.5g Agarose 50 mL of TAE 1x 1 uL ethyl bromide. Gel was run at 100V for 1 hour. The buffer used is also TAE.
01 March 2021 9,952 3 View
Hi, I am running a size exclusion chromatography experiment with a buffer containing Potassium Acetate as a salt. I analyse these fractions through SDS-PAGE. After boiling my SEC fractions in...
01 March 2021 2,622 3 View
I have used an AllPrep DNA/RNA/Protein Mini Kit QIAGEN kit to extract RNA and protein from my samples. At the end of the protein purification, I resuspend my protein in 5% SDS. Will these samples...
28 February 2021 7,370 3 View
I am trying to classify and analyze the results of an SDS-PAGE based array for bacterial detection using machine learning, but I have trouble finding the best way to represent the results with...
27 February 2021 9,176 3 View
I am worried about this overexposure of the upper part of the gel in the picture. Is it possible that this is the result of too much concentration of ethidium bromide? Why is there such a big...
25 February 2021 8,140 3 View