Dear All,

I'm involving in a 2-way FSI problem simulation (transient structural + Fluent) which includes big structural deformation. I have used very small time step for transient structural part as well as system coupling part. However, system coupling delivers "highly distorted elements error" every time I run the problem. When I run the transient structutal alone, everything is OK. But, when I run system coupling it return highly distorted elements error for the first iteration, even for very small time steps (1e-6 sec). The loading is a distributed pressure with a magnitude of 4000 Pa. Anyone has any idea how to solve this issue??

Thanks,

More Mohammad Malekan's questions See All