Does anyone have a good protocol for COMET assay for plant root tissue?
Although a few years ago, we had some nice results with the COMET assay using the protocol described in http://www.ncbi.nlm.nih.gov/pubmed/?term=Parlesak+Comet.
HAve success, Alex
The protocol used by myself recently.
Thanks guys. I plan on doing the COMET assay soon. Will keep guys in touch.
Plasmid size:40kb E.coli strain: DH5 alpha I have tried using Qiagen midi prep plus kit with no luck. I need at least 100ng/ul concentration for sequencing. I have also tried the routine manual...
10 November 2014 4,404 19 View
Hi I was wondering if there is any online software to check the Tm specifically for PCR product?
09 October 2014 1,395 16 View
I have more than 300 plants to genotype. I am trying to find something quick which can be done in 96 well or any protocol which is feasible for large number of plants. I plan on performing PCR...
08 September 2014 4,909 8 View
Instead of checking only the mRNA level, I want to check the active protein level of MMP-1 in Liver tissue from mice. How can I do that?
03 March 2021 1,763 2 View
Hi, I have problems with running gel electrophoresis. I have tried agarose gel electrophoresis and native PAGE. I have two proteins, which have molecular weights of ~30kDa and ~180kDa and two...
03 March 2021 4,275 4 View
i have problem in preparation of liver tissue with bad cell organelles and how i can adjust osmolarity
03 March 2021 8,890 1 View
Gel electrophoresis, RNA degradation, RNA extraction from fresh tissue
02 March 2021 5,433 5 View
02 March 2021 3,060 3 View
Question to you and THEM, the New Journal, "Integrative Psychological and Behavioral Science" -- do you not know, and have you not seen, this done before? There appears to be a core problem for...
02 March 2021 3,024 2 View
I am searching for a good place for the Post Doc,
02 March 2021 4,053 3 View
I'd like to perform single-strand conformation polymorphism (SSCP) in my thesis, however I cannot control the temperature of the vertical PAGE since we are using the conventional tanks. Is there a...
02 March 2021 9,157 1 View
I am going to have 3 different probes in my qPCR work that I am going to do. But I realized that the machine we have in the lab is a Rotor-Gene Q 2plex HRM Platform, saying it has green, yellow,...
01 March 2021 8,544 1 View
Can someone please give me some possible things that could go wrong? Here is my recipe: 0.5g Agarose 50 mL of TAE 1x 1 uL ethyl bromide. Gel was run at 100V for 1 hour. The buffer used is also TAE.