Contact experts in Material Characterization to get answers
2,044 views 1,593 posts
Questions related to Material Characterization
I am developing a permeable membrane. (1) what is the best technique to determine pore size of the membrane ? (2) how to control the pore size ?
01 January 2017 2,950 8 View
The first two pictures for the TiO2 CNF and others for RGO TiO2 CNF
12 December 2016 7,039 3 View
I want to find near boundary gradient zone for my samples,I tried using point to point misorientation from profile vector,but i am confused about criteria of NBGZ.
12 December 2016 4,324 4 View
I am a little bit confused about relationship among PL intensity, surface states and crystallinity. One says that higher PL intensity, the solid will have less surface states and better...
12 December 2016 2,765 11 View
What can I do with STXM and TXM on Li ion battery? Is there any good beginner level introductory paper or information? Thank you guys.
12 December 2016 6,070 1 View
I wish to peform a contact angle measurement on a single PCL fiber with diameters ranging from 2 to 10 micrometers. Is there any publications that have used such methods/instruments? Thanks
12 December 2016 5,249 5 View
During the decomposition of C 1s XPS spectrum, the sp2 peak (284.7 eV) of the sample contains high a mount of diamond is shifted to the high binding energy side when comparing to sp2 (284.5 eV)...
12 December 2016 8,168 4 View
Dear researchers I need to perform 95Mo NMR analysis. Is there anyone who knows where I can have it done?
12 December 2016 1,233 0 View
09 December 2016 3,026 3 View
09 December 2016 3,908 10 View
Hi guys. Recently I just started to learn how to conduct a fracture toughness test on my material. The test method I use is ASTM D5045-14. The yield stress of material must be used in this test....
06 December 2016 1,650 8 View
I have a Raman Spectra of Alumina and 3Y-TZP sintered around 1500 C. The Raman Spectra is showing few small peaks above 1000 cm-1 and one peak around 1650 cm-1. As most literature does not...
27 November 2016 568 2 View
If i deposit a layer of thiophenol on a gold surface,how i can calculate average coverage area if i get a circle deposit layer and i measured its radius
19 November 2016 3,628 2 View
I conducted tensile and flexural tests for 4 different anisotropic materials (Fibre reinforced plastic). I got tensile strength of material C higher than material N. Whereas, higher flexural...
12 November 2016 2,935 6 View
11 November 2016 8,111 3 View
Suppose I have two surfaces, one shows p(2x1) twin domain structure and other shows combination of both p(2x1) twin domain as well as c(2x2) structure. Now if we compare the LEED-IV for the...
11 November 2016 7,986 0 View
11 November 2016 2,534 7 View
Please let me know the procedure of taking FTIR of a liquid sample using KBr pellet. You are welcome if you know the way by using different type of pellet (like NaCl) as well.
11 November 2016 6,852 9 View
As far as I understood the concept of packing, a cubic or hexagonal closed-packed (ccp or hcp) arrangement of atoms as in austenite (gamma-Fe), Ni, Cu etc represents the most dense packing of...
11 November 2016 3,495 16 View
It is a grey iron with 3.5% C, 1.4% Si , 0.8% Mo, 0.3% Cr and 0.1% Cu and also with late inoculation. The microstructure is containing pearlite, graphite ferrite, and some small carbide. But I...
11 November 2016 9,799 10 View
I used solgel method to synthesize O3 type NaNi1/3Co1/3Mn1/3O2. I did XRD the achieved data from XRD is attached in file. I want to confirm that the material i synthesized is NaNi1/3Co1/3Mn1/3O2....
11 November 2016 1,737 9 View
Dear researchers is there any difference between photoluminescence setup of thin film samples and liquid samples? for thin film samples, reflection is important. what about liquid ones? does...
11 November 2016 7,384 0 View
I have copper foils bough commercially and I am looking to perform simple chemical treatments on the foil that will result in ultra smooth surface i.e.Rz
25 October 2016 4,077 8 View
I am trying to study the hydration of hydrated cementitious binder at different days of curing. The samples are in 40 x 40 x 160 prisms. I intend slicing them into 8mm thick samples. If these...
24 October 2016 7,938 14 View