I extracted phycobilin compound using 50% methanol (sample) as phycobilin is water soluble. I have tried mixture of hexane and ethyl acetate in ratio (2:1) as mobile phase and silica gel as stationary phase. The band separated but doesn't eluate.
Thank you Dr.Krishnasarma for the guidance.
Run a TLC. The solvent yielding an Rf of 0.5 will be your solvent of choice (in case you use flash silica for your columns and gradient elution).
I am looking to remove an heavy metal by ion exchange column. The concentration of heavy metal in the water is only 25 ppb. I had already got the equilibrium isotherm capacity at 25 ppb. Assuming...
07 September 2020 6,194 2 View
I have waste water which has some dissolved metal (in ppb) and the same metal in a precipitated salt form (in ppb). My aim is to find accurately dissolved metal concentration. Whether 0.45 micron...
23 March 2020 6,868 7 View
03 March 2021 8,272 1 View
I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
I looking for ferro calcium production process
03 March 2021 1,755 4 View
I am using a 2707 waters HPLC device. When I try to inject a sample, it says missing plate or rack. I changed the needle and calibrated its position but I still get the same problem. I even get...
02 March 2021 1,408 1 View
(This statement is from wikipedia, BTW). What is so special about metallic bond that is limiting high-P low-T state of a matter (as long as individual atoms exist, not white dwarf of neutron star...
02 March 2021 3,309 2 View
Hello! I'll do a size exclusion chromatography, but I only have an open column, and I'll perform the peptide extraction from yeast, using buffer lysis (sodium phosphate 50 mM/NaCl 30 mM/DNAse and...
01 March 2021 2,215 2 View
I am going to have 3 different probes in my qPCR work that I am going to do. But I realized that the machine we have in the lab is a Rotor-Gene Q 2plex HRM Platform, saying it has green, yellow,...
01 March 2021 8,544 1 View
I have designed reflectarray element to generate OAM beams at 5.8GHz and feeding it though Horn Antenna on HFSS. After full wave simulation, i am not getting desired results i.e Radiation pattern...
01 March 2021 9,701 5 View
Hi, I am running a size exclusion chromatography experiment with a buffer containing Potassium Acetate as a salt. I analyse these fractions through SDS-PAGE. After boiling my SEC fractions in...
01 March 2021 2,622 3 View
I am doing my thesis on the nutrient deprivation on the macroalgae Rhizoclonium sp. I will be analysing the levels over a period of roughly 5 days by HPLC-UV and GC/MS. I will be using seawater as...
28 February 2021 6,477 1 View