you can use Trizol or Tri reagent instead of phenol followed by chloroform IAA extraction
Alternatively most companies like Qiagen Ambion (Gibco life Sciences) thermofisher and Sigma make purification Columns
The advantage of column based procedures is that you avoid using toxic chemicals like phenol or Trizol
The disadvantage is that they cope less well with impurities in the starting materials and tend to saturate
Thus columns are perfect for small amounts of clean tissue culture cells whereas extraction of RNA from larger quantities of tissue is best performed with phenol or Trizol