13 February 2023 1 257 Report

The residual stress of the additive manufactured aluminum alloy was measured using neutron diffraction (refer to the picture below for the sample shape).

The residual stress result measured by neutron diffraction method is shown in the figure below.

According to the results of several papers, LD and TD values show similar results, and ND values show different results.

However, my experimental results showed that the LD and ND results were similar, but the TD results were different.

These results do not explain well, please suggest any possibility.

More Sc Park's questions See All
Similar questions and discussions