Good day, my culture was mesophile and anaerobic. May I know which plate will be suitable for it? Thank you.
Pour plate.
If you have an anaerobic chamber you can also use spread plate. Incubate in anaerobic jar.
For SRBs semisolid Postgate E medium in Bijou bottles is used.
Robert Thomas Bachmann thanks, may I know how about the selection of plate for facultative anaerobes and mesophile?
In the case of facultative bacteria both spread plate and pour plate should be ok. Just ensure you incubate at ~35°C.
Robert Thomas Bachmann thanks a lot! :)
Good day, may I know if I had 8Kda and 56Kda protein can I used the sds gel protocol that is suitable for 8Kda one for 56Kda protein as well? Or I need to do 2 different formulae for these 2...
04 May 2019 1,621 2 View
Hi. May I know how much in percentage of both stacking gel and separating gel for protein size around 56kDa? Thank you.
03 April 2019 8,121 3 View
Good day, I would like to know more on tips and precautions for fermentation step in yogurt drink (such as YAKULT). If can provide any supportive journal, then is much more better. Also, is there...
05 January 2019 4,242 2 View
31 December 2018 3,607 2 View
23 December 2018 1,322 3 View
Good day, I got cfu count for 1.8 x 10^8 in 10^-5, 1.3 x 10^9 in 10^-6 and 5.7 x 10^9 in 10^-7 in my triplicate serial dilution for L. lactis subsp. cremoris. Although the cfu count per plate was...
11 December 2018 6,525 0 View
Good day. I am looking for standard growth curve for L. lactis subsp. Cremoris (NZ9000) of 600 nm optical density versus 10^7 cfu/ml with. Purpose is to see when this LAB reaches its' log phase....
11 December 2018 1,104 12 View
When I conducted the degassing experiment using decompression under anaerobic condition(and I used ferrous based chelating agent), the oxidized ferric were observerd. So, could you tell me the...
03 March 2021 4,892 5 View
I'm a graduate student who works with an anaerobe, so I often work in an anaerobic chamber. I've been working on an assay that involves the steady-state of the quinone/ quinol pool. Anoxic...
03 March 2021 2,971 1 View
I am using a 2707 waters HPLC device. When I try to inject a sample, it says missing plate or rack. I changed the needle and calibrated its position but I still get the same problem. I even get...
02 March 2021 1,408 1 View
We have HUVEC bought from Invitrogen. Cat no -C-003-5c. while first plating the cells we have bought the protocol suggests not to centrifuge the cell with media to remove the DMSO. Should we...
02 March 2021 3,713 2 View
Good afternoon, I recently used OmniLog from BIOLOG for my experimentations : I tested the metabolism of different strains on 2 types of plates. I have 16 strains of 3 different groups...
02 March 2021 3,584 1 View
We have always used the 96 welled plate, the 48 welled plate but apparently there is much evidence on the 24 welled plate and above all its benefits.It states it is the same you would use on ELISA...
28 February 2021 1,149 1 View
Hi, recently I encountered a protocol for plating which was not the usual method I have been practicing (pour LB agar onto plate, allow it to solidify, pipette bacterial suspension onto plate,...
28 February 2021 7,292 3 View
Hello, recently I am having some difficulties with maintaining the cell culture of primary cells isolated from a skin biopsy (normal and malignant). The coating of culture plates with Matrigel (a...
26 February 2021 6,151 2 View
I am facing difficulties in cloning a 1kb gene into a vector (pJIT163). I have my gene on interest (GOI) in pUC57 and want to clone in pJIT163 using SalI and BamHI restriction sites. I am getting...
25 February 2021 3,221 7 View
Hello I'm currently working on a topic related to studying the anaerobic biodegradation of TPH in marine sediments. In this work, sediment should be mixed with fuel oil to a concentration of 20 g...
24 February 2021 9,839 3 View