Dear All,
I would like to make my own native gels.
Have recipes on Tris-Glycine running buffer and TRIS Glycine Native sample buffer.
Would like to make TRIS Acetate gels, discontinous, 7%.
Cannot buy precast gels.
Any suggestions?
Best,
Hendrike
I am looking for such standards that are applicable in the following countries (or at least one of them): Brazil China India Russia USA I highly appreciate your support.
06 August 2015 3,220 7 View
I got these smeared bands quite often lately. We typically run the gel at 140V with a 10-12% gel and do a wet transfer at 220 mA for 1.5 hr in cold room. We also noticed some dirty spots/dots (see...
10 August 2024 7,480 3 View
Does anyone tried to do nucleofection with AMAXA by Lonza with lower than recommended amount of buffer in the cuvettes (100 ul)?
07 August 2024 4,616 0 View
Currently, when I run SDS-PAGE, I don't see any bands at all, even though I used the same material just a day ago and it worked fine.... In our lab, we dilute the 10X running buffer to 1X and...
06 August 2024 5,373 2 View
I have been working on Red blood cell-derived extracellular vesicles as Antisense Oligonucleotide (ASO) carriers. We normally run agarose gel to quantify the loading efficiency. I used naked ASO...
06 August 2024 3,130 2 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
I am having an issue with my gel image where my PCR product is not appearing very bright on the gel. When I perform gel extraction, the A260/280 purity value is very low. I used the Qiagen gel...
05 August 2024 9,798 3 View
Is it the "elution buffer" or the "dialysis buffer"? Note: I'll be using NanoDrop OneC
01 August 2024 967 3 View
Hello everyone, I performed a PCR yesterday, and the results showed no bands on the gel. Of course, I probably missed some crucial steps, like adding my samples to the PCR strips themselves, for...
31 July 2024 2,406 6 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
I am using CuBr/THPTA for a click reaction in total cell lysates. I am facing issues with my protein sample in non-reducing SDS-PAGE where it's not migrating properly and most of it remains at the...
29 July 2024 950 4 View