I have to mark very very small (0.001 mm) permanent dot on steel specimen as a reference point.
Hi!
One possibility is to use micro hardness indents with a indentation force adjusted to the hardness of your sample!
Good luck!
Have you considered using a laser to etch the surface?
No sir, You mean laser engraving?
Yes, you could call the technique laser engraving. But I understand you only want a micron size dot.
Thanks sir. I want micron size dot only as a reference for measurement.
Hello sir,
Nano indentation will help you, to put accurately put up 0.001mm dent or dot.
Refer this website for facility:
https://www.ircc.iitb.ac.in/IRCC-Webpage/rnd/CentralFacilityRegistration.jsp
Thank you sir. I will see.
Need to bond Stainless steel orthodontic bracket on steel bar and twist the archwire for 50 degree.It should not get debond during archwire twist.
10 November 2017 1,114 1 View
Need to rotate 10000 nodes to 5 degree, 10 degree upto 50 degrees.
09 October 2017 7,643 0 View
Planned to attach a C clamp like stiff wire on 0.482 mm x 0.64 mm rectangular dental archwire. Is there any possibility? Constraint is that C clamp must with stand applied force (Rotation)...
05 June 2017 5,803 1 View
When we twist a bar inside a slot bar had contact on slot walls. Problem is bar is penetrating inside the wall. How to avoid. Contacts were made in Hypermesh, analysis done in ansys apdl.
08 September 2016 9,549 3 View
Need to find at what load plastic deformation takes place.
08 September 2015 7,425 0 View
I did multiple load steps with ansys transient, after some time when i applied zero force, my model gives some deflection, but within elastic limit, i think that deflection (DMX) should be zero,...
08 September 2015 9,088 7 View
05 June 2015 9,344 5 View
I wish to do loading and unloading through ansys. i able to do transient time load step but i dont know how to do reverse loading?
05 June 2015 4,665 4 View
06 July 2014 7,792 5 View
Time varying load step.
05 June 2014 4,218 9 View
I looking for ferro calcium production process
03 March 2021 1,755 4 View
Hello everyone. Given microstructure image belongs to a 12% ledeburitic cold work tool steel (annealed and tempered). The sample was etched with picral (100 mL ethanol and 4 g picric acid). I...
02 March 2021 4,119 3 View
It is oftentimes said to be a distinctive metallographic trait that differentiates a fully austenitic and a fully felly ferritic steel without etching that might distinguish between two. Why...
02 March 2021 728 2 View
As I was tweaking step-by-step OpenCalphad6 Macros step1.ocm involving phase and thermal property calculation of a High-speed steel, I could not incorporate more than 6 elements in the steel...
01 March 2021 8,840 1 View
I have a structure that employs d-ring swiveling tie-downs that corrode during use and become "frozen". I have sample swivel assemblies that I wish to corrode to see if I can free them using one...
01 March 2021 3,739 3 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
My main concern is that the metal powders should not weld to the mold surface and I should easily be able to eject out the pressed samples. I am looking for alternative for graphite moulds. The...
22 February 2021 2,965 4 View
Dear all, If steel jacketing is used to retrofit a reinforced-concrete (RC) column, can we use it to improve flexural strength? I understand that we leave gaps between the ends of the jacket and...
22 February 2021 1,906 5 View
Hi all, Does SeismoStruct support modeling rectangular RC columns retrofitted with steel jackets (e.g. rectangular, elliptical) ? Any suggestions for other software (apart from...
20 February 2021 4,521 1 View
How do the thermal conductivity, specific heat capacity, plastic strain, critical compressive displacement, and thermal expansion of both hot-rolled steel and concrete change after cooling based...
15 February 2021 1,385 5 View