I have a problem interpreting the results of acridine orange by flow cytometry. Do we see red fluorescent in cells with increased autophagy and green fluorescent in suppressed ones? And if so, should we report the ratio?
Acridine Orange is not a selective marker of autophagy. I suggest you read carefully the review followed by most people in this field:
Klionsky DJ et al - Guidelines for the use and interpretation of assays for monitoring autophagy. Autophagy 12 (1), 1-222, 2016.
When I conducted the degassing experiment using decompression under anaerobic condition(and I used ferrous based chelating agent), the oxidized ferric were observerd. So, could you tell me the...
03 March 2021 4,892 5 View
Hi, I am after the reference below, my library says it cannot obtain a copy either locally or internationally, any help appreciated! Chris Wang ZM, Heshka S, Wielopolski L, Pi-Sunyer FX, Pierson...
03 March 2021 6,193 1 View
We have synthesized various metal complexes with different environment around the metals. Now to see the application of synthesized complexes we need this study also. we are also interested in...
01 March 2021 1,899 2 View
Which is suitable for use with Python? MySQL or SQL Server? What is your suggestion?
01 March 2021 3,422 3 View
Hello everyone. I have conducted the research on post harvest longevity of tomato crop using plastic packaging and different doses of chemicals as two different factors. The design of experiment I...
28 February 2021 8,189 3 View
The antimicrobial effect of local anesthetics has been known for more than 50 years, but it still seems to have an unclear mechanism of action. which bacteria? which concentration? etc etc. ....
27 February 2021 4,450 2 View
24 February 2021 5,378 1 View
In the PVD of TiN thin films (~100A), I've found the resistivity of the TiN films dropped from ~100 to 60um*cm with N2 flow increasing up to the metallic mode ending point; then the resistivity...
21 February 2021 1,864 2 View
About crack modeling in ABAQUS: Mode I (pure-tensile cracking) and Mode II (pure-shear cracking), these assumptions may be accruing in theoretical approach (ABAQUS) not practical in Lab....
19 February 2021 6,156 1 View
hi everyone I am simulating a unit cell structure in HFSS using Flouquet port having two modes for absorption I have used this formula:- absorption=...
17 February 2021 9,178 2 View
Is There Any Feasible Method To Test The Efficiency Of Fluorescent Compounds Other Than UV Spectrometers ? Suggestions Would Be Appreciated !
02 March 2021 5,785 3 View
Dear all, I just saw this example in FB on the difference between laminar flow and turbulent flow. The flow from a pipe hits the sink and scattered. The flow from the pipe is characterized as...
02 March 2021 1,999 5 View
Hello Everyone. Currently I am working to characterize macrophages in the myocardium after ischemia-reperfusion injury in rats. Due to the low total cell number isolated from rat hearts I can...
01 March 2021 3,867 3 View
I have a set of stably transfected cell lines all transfected with plasmids containing GFP tags on the C terminus. During a western blot using anti-GFP antibody, one of my plasmids has dissociated...
01 March 2021 9,310 4 View
Hi all, I have been working on the quantification of chitin in insect samples and feed for a while but I can notice that the quantification methods (e.g. exposure to HCl, NaOH, and weighing sample...
01 March 2021 1,843 2 View
I am growing the cells on coverslips and transfecting the fluorescent tagged protein directly on them. Then i want to observe these cells under confocal microscope. Currently i am just using...
01 March 2021 6,142 3 View
I'm a student and I have to produce a cell line with a knockin for the NRF2 gene with GFP. I have to put a promotor in front of the GFP because the gene will be too far away from the promotor of...
28 February 2021 7,127 2 View
Is there any reason for decrease in fluorescence emission intensity of HSA,BSA when increase the concentration ?
28 February 2021 3,653 4 View
Is the period to autoclave not enough? The inoculation in a hood and flame and UV and alcohol.
27 February 2021 9,356 3 View
Dear All, We are using Autodesk cfd to calculate the air flow in a single sided naturally ventilated room, where air flow depends only on buoyancy due to temperature difference between inside and...