I need to assay lipid conjugated dienes in food sample using UV derivative spectroscopy? I have no any information about how to do it?
hi, you can see this article
http://link.springer.com/article/10.1007/BF02540920#page-1
The reason for using derivative spectroscopy is the complicated spectral envelop you have. I strongly recommed you to find the book of Talsky for derivative spectroscopy. Probably you will find more information how to handle your system.
I'm trying to use new organic compounds as a remedy for sperm membrane injury, I want to use lysosomes as delivering vehicles? can any one give me an easy method for liposome preparation?
03 April 2018 1,567 3 View
I'm working on the use of DPPH in the biological system, I need o dissolve DPPH in buffer system , but DPPH is soluble in methanol and not soluble in aqueous solutions . how can I dissolve it.
01 February 2018 481 0 View
I use Aebi method in the assay of catalase, but i have a problem : the absorbency is unstable which mean that the numbers increase and decrease rapidly.
10 November 2015 2,902 34 View
I want an rapid and easy staining method for determining sperm morphology.
09 October 2015 2,961 5 View
I want to do my experiment o male infertility via inducing it in mice, what is the chemical method for inducing infertility.
08 September 2015 8,009 14 View
I need a free program or a method for determination of IC50 in DPPH method of antioxidant assay.
08 September 2015 3,897 2 View
See above
08 September 2014 5,995 9 View
I used Aebi method foe CATALASE assay but the equation result is reaction rate (K), how I can convert it to international unit.
08 September 2014 5,854 0 View
in the estimation of Catalase the method assay K value, what is the equation to convert it ti IU.
06 July 2014 2,569 0 View
Assay of COX inhibition ability of plant extracts.
05 June 2014 10,200 0 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
I'm researching light sources and their UV emissions. I'm curious if a 50W, 7500K conventional LED lamp emits any UV light. I found that a 200W tungsten lamp can emit up to 1.5 mW/cm² at 350 nm....
31 July 2024 3,843 7 View
Following curve related to Co0.6Mn0.4Fe2O4 Magnetic nanoparticles with extra phase a-Fe2O3. I will appreciate to help me to interpretation this spectroscopy, especially the blue line.
31 July 2024 9,140 2 View
Hello everyone, I am new to this characterization but watching videos on youtube I have already plotted a Nyquist plot (Z' and -Z'') and already fitted models on my material using Zsim. But now I...
29 July 2024 1,376 0 View
How can we calculate the percentage of configuration interaction (CI) in the UV output data of the Gaussian program? for example: Excited State 17: Singlet-A 5.1359 eV 241.41 nm...
28 July 2024 9,165 2 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
In the context of Electron Spin Resonance (ESR) spectroscopy, under what conditions is an absorption spectrum considered to be a single absorption spectrum?
25 July 2024 2,325 1 View
Though much literature suggests fitting a Voigt profile on a LIBS peak, is it also possible to fit a Gaussian profile on the LIBS peak? I have 204 spectra files, and I am building a pipeline for...
23 July 2024 6,127 1 View