11 November 2014 11 4K Report

Hi,

I am doing phase-change simulation now. I have got some problems about creating interface. At the evaporation interface, there are two edges overlapping, one belongs to channel zone, the other belongs to porous zone.

So when I creat interface in FLuent, I should creat interface with porous-up and channel-up as condensation interface;porous-down and channel-down as evaporation interface. But when I set like above, there is a divergence with energy.

However, when I creat interface with porous-up and channel-down, the temperature distribution is good.

The weirdest thing is that I can even creat interface with porous-up and channel-left, even though their sizes do not match.

Could anyone tell me the principle of creating interface? How should I treat the interface when I want evaporation only occurs at the wick-vapor interface.I do not want the liquid flows into the channel zone, but only after the liquid turns into vapor.

Thank you.

Regards,

Bill

More Yibiao Wang's questions See All
Similar questions and discussions