GO in NMP - considering NMP is not an electrilyte on itself, can the flakes move towards the opposite electrode?
adding graphene oxide / rGO / graphene have shown conflicting surface roughness changes in Polyethersulfone. for rGO in specific, why do we have roughness decrease whilst porosity has increased?
01 February 2019 9,601 5 View
when the loadings of GO in the polymer increased the contacact angle was almost the same as the pure polymer and in one case higher... what can be the reason ... it is expected to have more...
04 May 2018 7,944 3 View
when I apply an electric field over my polymer solution it tries to move toward the negative electrode (the distance between the two electrodes is very low) this local movement is different every...
02 March 2018 9,968 4 View
while casting a carbon filler /polymer composite membrane on glass, during inversion in water , it gets up with a convex surface which is a little shiny. is this side the top surface of the...
01 February 2018 7,868 9 View
when i want to try thick sectioning of my sample, I fill in the tray with water bu even with angular and axial regulations and also filling and vacuuming water , it does not wet the upper part !...
31 December 2017 6,374 6 View
I need to know the viscosity and dielectric of my solution. (polymer in a polar solvent)please advise if there is simple models or estimation techniques just to know an approximate estimation
31 December 2017 5,926 2 View
I need to cover a metal surface with a thin layer of a water soluble polymer and this layer should adhere very well and not separate , also no-toxic ... what are the feasible methods?please...
31 December 2017 3,620 10 View
my membranes are produced about 4.5 cm . is it possible to test them by a sterlitech HP4750 cell with some modifications of the setup?
11 December 2017 3,742 2 View
when we are using phase inversion method, how can we avoid formation of holes in the film casting on a glass slide? what parameters are effective?
09 October 2017 4,670 1 View
when we have nanoparticles in a polymeric solvent and it is not moving (hydrostatic), should we consider inertia for the particles negligible vs viscose forces? - and how would that be in case of...
08 September 2017 2,290 4 View
Hi, I have problems with running gel electrophoresis. I have tried agarose gel electrophoresis and native PAGE. I have two proteins, which have molecular weights of ~30kDa and ~180kDa and two...
03 March 2021 4,275 4 View
Gel electrophoresis, RNA degradation, RNA extraction from fresh tissue
02 March 2021 5,433 5 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I'd like to perform single-strand conformation polymorphism (SSCP) in my thesis, however I cannot control the temperature of the vertical PAGE since we are using the conventional tanks. Is there a...
02 March 2021 9,157 1 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
In the stabilization of AgNPs are vital in current research interest. However, some of the 2D nano-materials like graphene oxide, MoS2, etc... previously used to stabilize it. But still they shown...
01 March 2021 2,207 3 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
I am trying to reduce graphene oxide by thermally but I have no proper information regarding this. Can any one help me regarding the details about temperature and time for the reduction of...
23 February 2021 4,155 4 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...