Different literatures read spectrophotometer in different time, I am very confused how and when to read the numbers of spectrophotometer and how to zero it. Please let me know if you can clarify this to me. many thanks in advance
Perv, I always measure at 593nm. I blank/ zero it using FRAP reagent+water.
I hope this one will be useful
Best regards
..
05 August 2024 4,407 0 View
Aa
13 July 2024 2,909 2 View
11 July 2024 4,645 3 View
Ad
08 July 2024 6,928 4 View
Ab
26 June 2024 9,122 5 View
AB
23 June 2024 1,858 0 View
Have you ever seen a small number of cells, 50-100 thousand, after centrifugation as a dry pellet in an Eppendorf tube without a microscope? Are there methods to potentially stain the cells in the...
09 June 2024 6,311 0 View
I have 217 preprocessed BrainVision matlab files (.mat) with ECG data in them. I've been having trouble creating a study for these. I know BioSig works for ECG data, but it doesn't seem to work...
21 April 2024 1,028 2 View
I have 25 folders for 25 participants, all with .mat files inside that are preprocessed. Most of them have the same amount of .mat files - a couple participants didn't finish the study, so they...
17 April 2024 1,897 3 View
How the concept of oblivion is interwoven within psychoanalytic theory ?
24 February 2024 5,581 0 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
I'm currently working on calculating the collision cross section (CCS) for various ions, and I'm facing challenges when dealing with sodiated and multiply charged ions. Most of the resources I’ve...
08 August 2024 8,329 0 View
I am currently working on a project involving liposomes and need to determine the maximum volume of siRNA that can be added to a 2.5 mL liposome solution with a total lipid concentration of 10...
30 July 2024 6,420 1 View
Can an analytical method's limit of quantification (LOQ) be outside its linear dynamic range, or is it always required to be within it? Please provide a thorough explanation supported by verified...
29 July 2024 7,198 9 View
I am doing research on wear mechanism of the additive manufactured metal parts under dry condition. Please share the reference to start the analytical modelling of the wear prediction.
29 July 2024 6,115 0 View
Dear Siesta Users, I installed Siesta 5.0.1 and I want to use Grimme's D3 correction. According to the 5.0.1 manual, I could use a few parameters to include the D3 correction in the...
27 July 2024 5,748 0 View
It has been long known that EDC carbodiimide and NHS easter's half life agains hydrolysis are highly related to pH. However, very surprisingly, not yet found a paper giving a table/chart of their...
25 July 2024 8,738 0 View
it's important to know that we are using the inactive elements of Cs, Sr, Co
25 July 2024 1,553 2 View
I know the difference between instrumental LOD and method LOD but my query is - in case of any sample whose concentration is zero or not detected by the instrumental LOD, is it possible to get...
24 July 2024 6,592 5 View
I run mechanochemical reactions that involves the use of a large amount of catalyst (1:1 molar ratio to the reactant). When I try to understand the effect of amount of catalyst on the reaction, I...
23 July 2024 9,938 1 View