Diffusing the carbon into voids and dislocations formed by martensite however 650 c reqd to temper this martensite which will lead to formation of stable martensite. Hence, the martensite fraction would be more and tempering at lower temp however at 650 tempering, the martensite has turned to tempered martensite and corrosion resistance reduced owing to the lesser bct structure in the matrix.