Hello!

I am trying to make a deposition of a L-alfa-lecithin phospholipid in a gold substrate for electrochemical applications.

Nowadays, I am using a KSV minimicro through with a Wilhelmy paper plate. As subphase, using MilliQ 18.2MOHm resistance (pH 5.5), and dispersing 10 uL of a 1 mg/mL chloroform solution of lecithin on top of the subphase.

The problem is that:

- If I lock the barrier position, for example at 70 mm, the initial pressure is 30 mN/m, but right after the locking, the pressure keeps going down

- If I try to lock the pressure at 30 mN/m, the pressure keeps falling, so the barrier continues to compress, until it touches the paper plate.

Can some have any hypothesis of why the pressure keeps falling instead of stabilizing?

More Rodrigo Mancini's questions See All
Similar questions and discussions