Sequencing reaction protocol bigdye terminator kit
Dear Nelson see the page attached Bigdye Terminator Protocol. I have used and optimized this protocol during my PhD studies. This page is from my PhD thesis. Best of luck
look here..
http://www.woodrow.org/teachers/BIOLOGY03/Projects/group1/word/BDCycleSeqprotocols.pdf
Thank you very much for indeed for the tips. In fact .5 ul is the limit.
I have to deal with environmental samples collected from lakes, rivers and soil to check the diversity of microorganism uses flow cytometry. How to fix and preserve it?
07 August 2015 2,211 6 View
I am on the lookout for the Enhanced Yellow Fluorescent Protein (Aequorea victoria) DNA sequence. Does anyone know where I can find it? Thank you in advance
03 March 2021 3,568 1 View
I am going to have 3 different probes in my qPCR work that I am going to do. But I realized that the machine we have in the lab is a Rotor-Gene Q 2plex HRM Platform, saying it has green, yellow,...
01 March 2021 8,544 1 View
We are preparing some experiments based on irradiating cells under different conditions in order to evaluate the effects in terms of DNA damage, genetic expression, etc. As our project is...
01 March 2021 3,355 3 View
I am looking at the ATP1A2 (Sodium/Potassium ATPase alpha subunit 2) in two human neuronal cell lines. Expression levels of this protein seems to be almost equal when detected by one antibody....
01 March 2021 3,607 3 View
I performed site directed mutagenesis, transformation, and then I sent out plasmids for Sanger sequencing and found out that there is extension of DNA just before the stop codon. I am not sure...
27 February 2021 547 3 View
Hi I am a bit confused. They are asking me to find out the volume of DNA required in ul (a total of 30-100 ng for genomic DNA) from the DNA concentration in the nanodrop reading which was 404.8...
26 February 2021 5,029 2 View
Hi everyone, Illumina provides a list of primers to amplify with high taxonomic coverage the ITS1 region for further fungal sequencing, but I cannot find the exact amount necessary of each...
25 February 2021 6,969 3 View
I am trying to better understand the scope of DNA replication and sequencing errors, e.g. 1. I have seen similar error rates of 10e4 to 10e5 for cell & instrumental DNA replication,...
24 February 2021 4,397 3 View
I got a thin band and a thick band i guess it would be the genomic DNA and the 260/280 ratio is 3.
21 February 2021 6,523 6 View
I constructed a synthetic DNA library (scFv, VH-VL orientation) with a 3' reporter and 8x histag. I cloned and expressed this gene following which I performed an ELISA. The ELISA results suggested...
19 February 2021 7,006 5 View