I am using a single forward primer and two reverse primers.
Hi, I think this will help you: http://medicine.yale.edu/labs/henegariu/www/tavi/p05.html
Cheers, Nadine
Download this article
Application of less primer method to multiplex PCR
Multiplex PCR design strategy used for the simultaneous amplification
of 10 Y chromosome short tandem repeat (STR) loci
http://cstl.nist.gov/strbase/pub_pres/Schoske2003.pdf
Multiplex PCR: Critical Parameters and
Step-by-Step Protocol
http://www.biotechniques.com/multimedia/archive/00011/97233rr01_11727a.pdf
Look at this article also.
3pmole forwardprimer and 1.5 pmole each of reverse primer should be fine. I usually use 3pmole concentration for multiplex PCR
Should i design new primers or available primers will do..
09 October 2014 7,797 3 View
What is the reason for keeping the ligation reaction at 4 degree or 16 degree. I am using Quigen ligation kit. Why do we keep at different temperatures?
04 May 2013 9,964 7 View
I am using multiplex PCR of genomic DNA in groundnut. One is an allele specific primer and the other is a universal primer.
04 May 2013 9,042 22 View
What should be the amount of DNA in PCR reaction?
03 April 2013 5,201 5 View
The smiling that occurs when running a gel at higher voltage. it occurs at both ends and the bands form a smile.
03 April 2013 3,523 8 View
Hello, We would like to increase the yield of our PCR product. We are running a series of PCR reactions that is targeting ~1.1kb sequence. We begin each reaction with ~400pg of template DNA...
02 March 2021 4,029 3 View
I am going to have 3 different probes in my qPCR work that I am going to do. But I realized that the machine we have in the lab is a Rotor-Gene Q 2plex HRM Platform, saying it has green, yellow,...
01 March 2021 8,544 1 View
To dear Researchers, I was analyzing a series of concentration for estimation of Real-Time PCR efficiency. The concentration was 1:10. I used MS-excel to evaluate Slope. The result of slope was -8...
01 March 2021 8,683 4 View
Does anyone have the experience of using Taq Man probes in the QIAGEN Rotar- Gene qPCR machine?
01 March 2021 5,311 1 View
Dear All, mirna primer showing some problem in the melting curve? any idea why? As attached is the melting curve. The forward sequence is obtained from miRBase and reverse primer is universal.
28 February 2021 5,008 4 View
I performed site directed mutagenesis, transformation, and then I sent out plasmids for Sanger sequencing and found out that there is extension of DNA just before the stop codon. I am not sure...
27 February 2021 547 3 View
Hi, my question is about the heating of thermal cycler machines and I hope some of you had experienced a similar thing previously. There are two thermal cycler machines in the lab(BioRad) and for...
26 February 2021 4,777 4 View
Hi I am a bit confused. They are asking me to find out the volume of DNA required in ul (a total of 30-100 ng for genomic DNA) from the DNA concentration in the nanodrop reading which was 404.8...
26 February 2021 5,029 2 View
Hi everyone, Illumina provides a list of primers to amplify with high taxonomic coverage the ITS1 region for further fungal sequencing, but I cannot find the exact amount necessary of each...
25 February 2021 6,969 3 View
After transfection with the plasmid ( linearized ) and subcloning of the cell lines, RNA was extracted from the cell and then reverse transcripted to cDNA. When PCR reactions were run to verify...
25 February 2021 5,712 3 View