I will be running an ELISA and I would like to try using a carbonate-bicarbonate coating buffer with a 9.6pH. Does anyone know the correct amounts or percentages of the substances to dissolve into solution?
Coating Buffer 3.7 g Sodium Bicarbonate (NaHCO3) 0.64 g Sodium Carbonate (Na2CO3) 1 L of distilled water
https://www.bethyl.com/content/protocol_elisa_p3
Most manufacturers recommend 0,05 M carbonate-bicarbonate coating buffer (pH=9,6)
Recipe - 50mM carbonate/bicarbonate buffer:pH 9.6:
• Na2CO3 1.59g (n = 1,59/106=0,015 M )
• NaHCO3 2.93g (n = 2,93/84=0,035 M )
• Dissolve in 1 liter deionized water.
Coating Buffer, 0.05 M Carbonate-Bicarbonate, pH 9.6
3.7 g Sodium Bicarbonate (NaHCO3) 0.64 g Sodium Carbonate (Na2CO3) 1 L of distilled water
Great, thank you!
I am trying to develop and optimize my own indirect sandwhich ELISA by performing cherkerboard titration. I am currently checking different dilutions of the capture antibody against the antigen...
07 August 2019 8,271 8 View
I am developing and optimizing an ELISA and I was jsut wondering how you determine what the best concentrations of antibody and antigen are based off the OD values. I have performed checkerboard...
07 August 2019 6,428 4 View
I am developing my own ELISA for Factor V in mice, however I am having a hard time figuring out how I will be able to run a standard curve. I know people usually use a lypholized powder at a known...
06 July 2019 371 3 View
I am using a Gen 5 plate reader system and I am trying to set up a protocol to read a checkerboard titration for an indirect sandwich ELISA I am trying to develop. Would it be correct to define...
06 July 2019 1,724 1 View
I am looking into getting a plate washer for performing ELISAs to help with consistency and I was wondering if anyone had any reccomendations.
06 July 2019 810 4 View
I have 0.05 ml of an HRP conjugated antibody that is at a concentration of 1.0 mg/ml. The company reccomends starting at a 1:5,000 dilution, but proper working dilution needs to be optomized....
05 June 2019 2,960 2 View
How can I determine a good adhesion strength range for coatings on polymer surfaces, such as DLC on polymer substrates? Is there a specific threshold for adhesion strength (from T-peel tests)...
10 August 2024 942 3 View
I did PR spin coating on trench structure. I used AZ P4620 PR and the thickness or PR is around 11um. The substrate is Si. And my trench structure depth is 141um(negative way). Even though I...
08 August 2024 2,298 0 View
Does anyone tried to do nucleofection with AMAXA by Lonza with lower than recommended amount of buffer in the cuvettes (100 ul)?
07 August 2024 4,616 0 View
I have been getting a low plasma and no coating while doing rf sputtering of copper doped ZnS using a power of 140 watts and at pressure of 6.5x10-3 Mb.
07 August 2024 4,526 4 View
Dear QE-users, In the method where full MS positive mode and PRM mode are used, we always get an incorrect auxiliary gas reading (41 instead of 25). This only happens in this method; other...
06 August 2024 4,953 0 View
Currently, when I run SDS-PAGE, I don't see any bands at all, even though I used the same material just a day ago and it worked fine.... In our lab, we dilute the 10X running buffer to 1X and...
06 August 2024 5,373 2 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
Hello guys! Do you have experience running a Oaxaca-Blinder decomposition on R applying person weights. How do you suggest doing it? I have a variable PERWT which gives more information on how...
04 August 2024 6,033 0 View
Is it the "elution buffer" or the "dialysis buffer"? Note: I'll be using NanoDrop OneC
01 August 2024 967 3 View
Hello Everyone I have a question about structure for connectivity analysis on sources. My goal: preprocess and cut data into trials create headmodels, using template MRI file perform source...
30 July 2024 2,744 1 View