is any idea about the potential window for methyl parathion in bare glassy carbon electrode??
Size of the quantum dots is 2.3 nm after attachment on glassy carbon substrate, the size drastically increased to 40 nm. but shape of the Quantum dots is retained. is it due to aggregation?...
02 March 2019 2,062 3 View
is it possible to get high electrocatalytic activity with electrode with lower electroactive surface area? what are the factors affecting electrocatalytic activity of the modified electrodes?
05 June 2018 6,479 0 View
is it possible C-O bond formation like C-N bond in glassy carbon electrode in the basic condition? In alkaline condition is Carbon-Oxygen bond formation possible in glassy carbon electrode?
31 December 2017 1,140 0 View
How to find the exact structrue of carbon dots? i want to find the structure of carbon dots precursor for carbon dots was glucose is there any relation between precursor and structure of Carbon...
09 October 2017 8,278 1 View
BSA is bulky protein molecule. when it used as capping agent using borohydrate as reducing agent is it borohydrate to unfolding of Protein is there any change in the nature of protein and how it...
05 June 2017 6,279 3 View
please anyone help me to clean Glassy carbon electrode modified with AuNPs . how to remove AuNPs from Glassy carbon electrode surface and also from sides of electrode
04 May 2017 6,120 7 View
in the electrochemical determination of methyl parathion from laviron equation it follows 4 electron reduction while doing effect of pH i got 15 mV /pH i am, confused between laviron and nernst...
04 May 2017 4,533 0 View
in modified electrodes at particular pH, higher current and less negative potential are obtained. so, is there any relation between electroactive surface area and pH?
02 March 2017 8,398 0 View
please help to fine negative redox potential biomolecules like Hydrogen peroxide
01 February 2017 3,216 0 View
How to find the concentration of Carbon dots? from weight of the starting materials how to find the concentration of carbon dots. is there any relation between the total weight of the starting...
31 December 2016 2,962 1 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,628 1 View
How can I determine a good adhesion strength range for coatings on polymer surfaces, such as DLC on polymer substrates? Is there a specific threshold for adhesion strength (from T-peel tests)...
10 August 2024 940 3 View
How do interactions between the biosphere, the carbon cycle, and the water cycle impact global warming and interaction between the atmosphere and the hydrosphere?
09 August 2024 3,286 2 View
Global ‘Weather’ has stopped, as ‘aqua thermionic instituted by the ‘Global thermo atmospherics has instituted global thermodynamics of 120º C + and thus all waters are, or have boiled into a...
06 August 2024 8,714 0 View
I attempted to make a privately uploaded text public but a window appeared that said an error occurred. There was no explanation provided as to why there was an error or what might be done to...
05 August 2024 8,025 7 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,622 3 View
The starting material is a finely ground powder. Some particles contain more graphene than others.
30 July 2024 3,977 2 View
I am currently working on modeling FCC catalyst regeneration and have come across a point of uncertainty that I hope you can assist me with. In my previous models, I have utilized lumped kinetics...
30 July 2024 6,136 0 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 941 2 View