Bi-product along with methanol can be carbon monoxide, formaldehyde, formic acid and methane
As stated already, GC is method of choice for determination of MeOH. Please find application examples below:
http://www.sigmaaldrich.com/catalog/analytical/supelco/g005769
http://www.sigmaaldrich.com/catalog/analytical/supelco/7960685
I recommend you to use GC .It is much reliable for VOC.
GC technique on DB-624 column
Methanol is basically invisible in the UV (UV cutoff is ~205 nm) so the best method of analysis is GC.
Using stealth liposome is one of the best option to target cancer cells but it also destroys host cells because liposomes are not able to differentiate exactly between cancer cells and host cells....
31 December 2015 5,596 2 View
Hiiiii everyone! I have an enquiry on statistical analysis. I was looking for many forum and it's still cannot solve my problem. I want to compare means of two groups of data but only with two...
03 March 2021 8,796 3 View
03 March 2021 8,272 1 View
I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
I am on the lookout for the Enhanced Yellow Fluorescent Protein (Aequorea victoria) DNA sequence. Does anyone know where I can find it? Thank you in advance
03 March 2021 3,568 1 View
Hi, I want to start testing pitfall trap to obtain ants samples, but I need to conduct molecular analysis on those insects. So, what kind of fluid can I use? Ethanol expires too early and I need...
03 March 2021 5,978 5 View
What's the best way to measure growth rates in House sparrow chicks from day 2 to day 10? Since, the growth curve from day 2 to 10 won't be like the "Logistic curve" it might not follow logistic...
03 March 2021 1,401 3 View
I have conducted and published a systematic review and meta-analysis research with the topic related to public health and health pomotion (protocol was registed in PROSPERO). Now we want to...
03 March 2021 8,920 3 View
dear community, my model is based feature extraction from non stationary signals using discrete Wavelet Transform and then using statistical features then machine learning classifiers in order to...
03 March 2021 6,994 5 View
I just wanted to check if I need to run a linear regression separately if I am using PROCESS MACRO to run mediation analysis. Thank you.
02 March 2021 4,359 3 View
I am using a 2707 waters HPLC device. When I try to inject a sample, it says missing plate or rack. I changed the needle and calibrated its position but I still get the same problem. I even get...