I have a problem with l-lysine HCl peak in sample and standard as it appear with shoulder or broad.
I am looking for a method to determine D-Sorbitol using hplc UV detector.any one can help
04 May 2018 9,054 7 View
I have a problem in hplc analysis of L-cystine analysis that the peak of both sample and standard have negative absorbance. This the first trial . -UV detector at 500nm. -Mobile phase phosphate...
11 December 2017 8,108 2 View
In dissolution test for Abilify 5mg (aripiprazole) Results show high results about 110%, while maximum result should not exceed 104%(max. result in content uniformity test). This problem does not...
07 August 2017 7,559 2 View
We have RO station produce purified water of conductivity less than 1.5µs/cm. will be any problem if i use it for HPLC analysis after filter it through 0.22 micron filter
31 December 2016 2,693 4 View
In a monograph ,it said that the retention time of the peak is about 20.
10 November 2016 2,467 6 View
1- I have problem in shifting of retention time of a peak : During analysis of rebamipide, the peak of rebamipide shift forward. for example(Std at 20.0 and sample at 20.5), and as the sample set...
10 November 2016 1,481 10 View
mix consists of propylparaben as internal standard and glycyrrhizic acid, when i inject the mix only peak of internal std appear but when i inject each one alone each peak appear. using HPLC.my...
11 December 2014 9,946 13 View
When I prepare a volumetric standard solution, I want to determine its expiry date by taking in consideration that it is not mentioned in any reference. And if possible I need a protocol for it.
03 April 2014 6,820 4 View
My column is Pico-Tag Column, 60Å, 4 µm, 3.9 mm X 150 mm used technique for HPLC amino acid analysis. Used in PicoTag® Amino Acid Analysis of Protein Hydrolysates.
31 December 2013 9,199 1 View
I need to know if this method is the official for analysis or not?
09 October 2013 6,915 5 View
A crude extract of fungal culture using EtOH was subjected to column and TLC and partially purified compound was obtained. UV vis spectrum of the compound/s has max absorbance at 218nm. The...
11 August 2024 9,801 2 View
I would like to learn more about SPSS and Its application especially in regards to data analysis. Please suggest me how I can learn more about it. Thank you so much.
11 August 2024 9,101 4 View
I have reverse sequences (AB1 format), can I base on reverse DNA sequences to perform nucleotide alignment, convert nucleotides to amino acids and deposit the sequence in GenBank database?
11 August 2024 5,138 1 View
Can anyone explain this method? Especially the last statement where it says only at 1.5 to 2.5mins was the MS/MS connected to the UPLC. How is that possible, is it a feature in this specific...
11 August 2024 8,141 3 View
Hello, Why do i see this baseline drift when i compare my blank (black) to the sample (blue)? Any suggestions as to why this happened? Thank you!
11 August 2024 3,770 4 View
Willett, Shenoy et al. (2021) have developed a brain computer interface (BCI) that used neural signal collected from the hand area of the motor cortex (area M1) of a paralyzed patient. The...
10 August 2024 7,180 0 View
I'm currently exploring the application of Python in textile engineering, specifically in areas like data analysis, process automation, and the development of smart textiles. I'm interested in...
10 August 2024 7,429 2 View
How can I use the cif data obtained from rietveld refinement extracted via gsas2, for microstructural analysis using ETEX software?
09 August 2024 7,718 0 View
Hello experts, Does anyone know any free software about retention index prediction ?
08 August 2024 7,403 2 View
I'm currently working on calculating the collision cross section (CCS) for various ions, and I'm facing challenges when dealing with sodiated and multiply charged ions. Most of the resources I’ve...
08 August 2024 8,329 0 View