I want to understand possible other standard method of measuring cytokine except ELISA methods.
Hi Emmanuel. You can consider using bead arrays based on fluorescence (CBA/legendplex). They are quite sensitive and available as multiplex too.
Good luck
I agree with Ravi. In addition, you can try proteome profiler antibody array that allows more than 100 proteins in a single sample.
Please what are the cost implications especially from us in the low income Countries
I have attempted various methods, including homozygous gene disruption and CRISPR-Cas9, but have not achieved the desired results. It appears that the gene of interest is situated in a...
15 July 2024 3,977 1 View
Would an average spot welder suffice for welding tabs for pouch cell electrodes instead of an ultrasonic one? Why would an ultrasonic welder be better than a regular spot welder?
10 July 2024 8,763 0 View
The impact im looking for could be both positive and negative on the electric grid
18 June 2024 9,269 3 View
IT
09 June 2024 735 1 View
What are the major ethical issues to be considered while working on design and construction of electronics device in a research work.
03 June 2024 8,189 4 View
The impact of monetary policy and bank rate on the performance of deposit money banks in Nigeria
31 May 2024 7,587 1 View
The result from PlasmidFinder shows that the assembled genome harbored many plasmids. Consequently, I want to investigate whether the plasmids are encoded for ARGs. And determine if they are on...
08 May 2024 7,467 0 View
ls it possible to emerge the wi-fi and Li-fi in one device and regular them.
21 April 2024 9,292 0 View
The code needs to be able to work on a 28-bus system having cost as the objective function and constrain like transmission loss.
18 April 2024 3,349 1 View
I want to understand why most analyses conducted in Africa use GMM instead of other panel data estimation techniques.
16 April 2024 5,322 3 View
I am trying to adapt adherent CHO-K1 cells in F12K+10%FBS to suspension culture in only F12K, but in vain. I have followed Mirus bio as well as Thermo protocols, please suggest any alternative....
31 July 2024 3,756 0 View
I have done an experiment using luminex technique, measuring 46 analytes. but my sample size is less (N=6, for case and control each). However, i have put up the experimental set in duplicates....
31 July 2024 3,665 3 View
We have encountered an issue with the serum of mice being hemolyzed after the process of centrifugation. Could you please provide guidance to prevent hemolysis ?
29 July 2024 8,402 4 View
I am developing an ELISA kit for rotavirus A (G1P8 and G1P6). Does anyone know the weight (ng) of these two strains? Or to help me find their weight?
29 July 2024 3,138 2 View
Hi there! I'm hoping to to look at co-localisation of cytokines and markers of different brain cell types (e.g., neurons, astrocytes, microglia) in juvenile rat brains (postnatal day 28) that have...
23 July 2024 2,844 1 View
hi, I am facing difficulties in the développement of an ELISA sandwich. I have several experiences in developing ELISA but that’s the first time I can’t find any solution. My test is currently as...
16 July 2024 9,044 10 View
In many experiments where HK-2 cells were stimulated with TGF-β at 10 ng/mL for 48 hours, I observed that even in the control group, the baseline expression level of fibrosis proteins like FN1 and...
15 July 2024 1,929 2 View
I placed mice in metabolic cages to collect urine samples for analysis. However, the majority of the samples have dried up. Is there any way to retrieve the urine in those tubes without...
14 July 2024 6,724 0 View
Hello everyone. I am working on my LV concentration porject, I use 500Kda hollowfiber to do it. The HCP and BSA removal rate is nearly 80%, but last time, I failed to run it. The HCP hasn't been...
11 July 2024 5,380 0 View
Hello, So I have mouse brain tissue MS data from one of my predecessors and I have human serum data from the hospital that I collaborate with. We are trying to find markers for the diagnosis of...
11 July 2024 8,484 0 View