Dear community,
Here is my problem: We have amplified multiple plasmids of various size with chemically competent cells from TOPO kits that were at -80°C and were possibly expired. We got no results for the PUC19 control but got results for our plasmids (confirmed by restriction enzyme digestion). We tried multiple kits and puc19 thinking that maybe we would have different results but none worked. We even PCRed the Puc19 to verify its integrity and they were good.
We proceeded with our plasmid assembly with a brand new kit of electro competent cells this time. And here again the puc19 control didn't work but we got colonies in one of the transformation plates (results to come).
We've tripled check the concentration of ampicillin as well as the protocols, try to troubleshoot multiple times with all the various solutions that we could come up with, but still we cannot get any puc19 control to work.
Maybe I should mention that the ampicillin might be old as well but then why would it work for the transformation and not for the control?
Can someone help deciphering this situation please?