Respectful Researchers,
Can any one please help me to calculate the area II (green color) using origin and / or available software.How can i exact the charge and discharge values from this P - E loop.
Thanks in advance
Use Origin Gadgets - integrate (8.5 and above)
find the area under the curve (black) as you mentioned above
then subtract the same with the rectange edge you will get the area (Green)
Thanks
Thanks a lot
05 June 2016 4,044 0 View
I am attaching here DSC results of my powder sample. The following are the details of the sample. 1.the sample mass (13.190mg) 2. heating rate (10deg/min) 3. range (-100 to 500c) output files...
11 December 2014 2,553 13 View
For example, if we take the FTIR result of BiFeO3 powder sample, I get peaks at 449.80cm-1 & 593.14cm-1 which conforms the presence of O - Fe - O bending mode and Fe - O stretching mode ( Ref:...
09 October 2014 4,809 4 View
From the data of wavenumber vs absorbance from FTIR, i find that there are some peaks. from that, the wavelength and angular frequency of the BiFeO3 are calculated , also mass of the Bi, Fe and O...
08 September 2014 1,343 1 View
I have grown a Bismuth ferrite sample through solid state and I observed that there are some secondary phases due to iron sillenite (Bi25FeO40). I am in need of Bi25FeO40 CIF file to refine the...
01 February 2014 6,980 4 View
While getting a result from XRD single crystalline data, how do I identify the result match with the expected compound. Is there free data available?
04 May 2013 4,068 0 View
I have a set of stably transfected cell lines all transfected with plasmids containing GFP tags on the C terminus. During a western blot using anti-GFP antibody, one of my plasmids has dissociated...
01 March 2021 9,310 4 View
I'm a student and I have to produce a cell line with a knockin for the NRF2 gene with GFP. I have to put a promotor in front of the GFP because the gene will be too far away from the promotor of...
28 February 2021 7,127 2 View
Is the period to autoclave not enough? The inoculation in a hood and flame and UV and alcohol.
27 February 2021 9,356 3 View
I have set up a qPCR run on MxPro with SYBR green and ROX as a reference, however, when I go to the analysis section the program seems to only collect data for the dissociation curves and not the...
25 February 2021 8,039 1 View
I am trying to clone 2 copies of the same mammalian gene into the pSF-CMV-Ub-Puro Ascl (contains HindIII, KpnI and NheI cut sites) plasmid. This is what the final product is supposed to look like...
24 February 2021 6,310 3 View
I am currently working on my dissertation and want to explore the role of competence as a mediator between the effect of colour of clothes on voting intention (focus on Western countries)....
21 February 2021 8,609 1 View
What does the color of a spiro-ometad film indicate? I got purple, green, red, even black color of the spiro film. Is there anything we can get from the preliminary color analysis(e.g. oxidation...
21 February 2021 1,831 4 View
I work on estimation of alpha amylase activity using dinitrosalisylic acid reagent If i put the reagent to stope the enzymatic reaction and allow the reagent to react with the produced reducing...
17 February 2021 7,402 4 View
i have been doing cholinergic assay on natural product and for some of the samples, i get negative value for the inhibition activity. can anyone help me explain the meaning of the negative value...
17 February 2021 4,118 1 View
Hi there, my lab recently opted to use LavaLAMP from Lucigen instead of the Warmstart kit from NEB. However, Lucigen has yet to create a colormetric kit for RT-LAMP, and adding phenol-Red (pH...
17 February 2021 5,399 1 View