I am researching counter electrodes for DSSC application. How many characterization must I do? If I have characterized using EIS, must I characterize using cyclic voltametry?
Yeh, you should do CV also. Go through this review, it might help you.
http://pubs.rsc.org/en/content/articlepdf/2014/ta/c3ta13374e
hello, Im using the Electromagnetic Waves Beam Envelops interface in order to simulate two seperate structures: one is a waveguide inside silicon, second is just propagation inside a bulk of...
10 October 2020 6,184 2 View
Dear colleagues, Now I am working on BHJ solar cells with inverted structure. I have a case where the cathode's WF (~3.8 eV) is lower than acceptor LUMO (~3.9 eV). What would happen if the...
18 August 2020 9,367 3 View
I am working on portfolio optimization using lower partial moment of order 1, can someone help me how to implement LPM-1 in excel sheet using "tau" as my threshold value as 0.00% and order (n) as...
05 July 2020 2,510 1 View
I am looking for literature regarding sexual segregation in sandbar sharks (carcharhinus plumbeus). I was told once that males school but females are solitary, and I cannot find a reference...
07 May 2020 2,537 2 View
I am here using the avogadro program for the construction of molecular structures, before doing DFT calculations. I use H2O and Graphene as small molecules and their substrates.
07 May 2020 4,661 3 View
In imbalanced class classification task, accuracy is not good enough as a main evaluation. There are several alternative evaluation, i.e.: AUC, kappa coefficient and Matthew's correlation...
22 April 2019 794 9 View
Dear colleague, I try to make opv device using PTB7:PC70BM active layer. The solvent/additive of this active solution are Chlorobenzene and DIO. When I try to spin-coat a phosphomolybdic acid...
28 March 2019 7,675 7 View
Dear, How can I convert from ppm to %wt or %vol for stearic acid in solution? For example 200 ppm of stearic acid in 10 mL of ethanol contains 20 mg PEIE. Thanks Sincerely, Adi Prasetio
23 January 2019 8,510 3 View
I'm looking for a staining method or an antibody that'll work with antibody staining protocols for microscopy. I have a protein that I suspect enters the insect nerve tissue. I have specific...
10 January 2019 1,450 2 View
how can i simulate roughness surface of deposition thin film versus kinetic energy
17 October 2018 2,532 3 View
Hello everyone. Given microstructure image belongs to a 12% ledeburitic cold work tool steel (annealed and tempered). The sample was etched with picral (100 mL ethanol and 4 g picric acid). I...
02 March 2021 4,119 3 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
I notice that upon washing and air-drying of my RGO/SPCE surface and characterizing again via DPV, the current response towards ferricyanide probe significantly decreases. My worry is that the...
22 February 2021 5,324 3 View
What are the testing rate for electrodes recommended by ASTM for cochlear implants. I am currently doing the 15mm/min elongatio testing.
22 February 2021 1,515 1 View
One of my colleagues said, "the impedance you can measure with the three electrodes and with the specific sequence varying the frequency" Is it possible to configure the potenciostat without the...
21 February 2021 418 2 View
Hello everyone Do you have any information about this error 'The experiment was stopped by a potential overload on Vs (auxiliary electrode)' in Origamaster software? I tried everything possible,...
19 February 2021 3,152 7 View