Electrode preparation / mesh current collector / battery / Active material
For nickel mesh (current collector) you can use drop-casting method to apply slurry (electrode material) on substrate.
Dear Luna Lopez, there are two ways by which you can apply slurry on the current collector.
(1) You can apply it manually. But the problem by doing it manually is that the thickness of coated material may be irregular.
(2) By Desktop coating machine (Dr. blade). This is a very efficient method to uniformly apply a slurry of desired thickness on the current collector.
One of my friends, every night after falling asleep, his mouth would make a creaking sound after chewing something. This teeth grinding condition would continue until he woke up, and he didn't...
08 August 2024 1,366 5 View
Hello all, I wanted to know, can I use galaxy (USA, Europe or Australia) platform for analyzing the shotgun data, and can it be used for publication purpose as well? Thanks :)
06 August 2024 6,610 4 View
i have sorted anti-NP specific plasma cells from bone marrow of C57BL/6 mice at certain times after immunization with variable counts and isolated total RNA using TRIZOL method for RT-PCR using...
05 August 2024 8,835 1 View
Because I have realized that the world tends more and more to do open and free science and there is a trend more and more to choose free databases, free tools and open access platforms.
01 August 2024 10,046 1 View
Nothing
01 August 2024 755 1 View
Dear All, I am trying to transfect a pCDNA3.1 vector containing my gene of interest. The purpose is to figure out the localization of the protein of interest. I have fused the protein with GFP on...
31 July 2024 9,892 4 View
In a research, lesion diameter due to a disease has a CV below 10%. However, in an another parameter, disease inhibition percentage (compared to control), a value derived from lesion diameter...
27 July 2024 201 0 View
Hi, can someone please help me with their expertise. To analyse a dataset with 2 IV´s (2 levels each) and 1 DV (time - measured at 4 points, i. e. 4 DV?) I found the two-way repeated measures...
24 July 2024 3,284 6 View
Hello everyone! Someone working with Crispr Cas9. I have a question. Is it possible to edit a gene that is present on a plasmid (in this case with a low copy number)? In this case, is it possible...
22 July 2024 7,073 2 View
How to determine tannin content in fodder pellets?
22 July 2024 8,163 3 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
I imagine the battery drives the graphite into a carbocation, then chloride is oxidized to donate the electron to the carbocation, but what pushes the lost electrons of chloride to be shared...
03 August 2024 5,384 0 View
Regarding a model for simulating battery charge and discharge, what do you consider to be high fidelity? What is the acceptable percentage of error (regardless of the metric)? Could you suggest...
03 August 2024 5,358 0 View
I am an Mphil research student and looking for high impact factor battery related journals to download and read research articles to improve my knowledge and get new ideas in the field of battery...
01 August 2024 6,516 2 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View