Electrode preparation / mesh current collector / battery / Active material
For nickel mesh (current collector) you can use drop-casting method to apply slurry (electrode material) on substrate.
Dear Luna Lopez, there are two ways by which you can apply slurry on the current collector.
(1) You can apply it manually. But the problem by doing it manually is that the thickness of coated material may be irregular.
(2) By Desktop coating machine (Dr. blade). This is a very efficient method to uniformly apply a slurry of desired thickness on the current collector.
Light is inevitable for the process of photosynthesis reaction. Naturally sunlight plays the vital role for this process. Light may be of different colours like white, red, yellow, blue etc....
02 March 2021 7,890 2 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
There are different kinds of food stuffs which we intake daily according to our requirements. Carbohydrate, protein, fat, mineral, vitamin, water are mainly working for the growth and development...
01 March 2021 831 2 View
I want to build a low-cost polarimeter to study circular dichroism (chirality). What type of samples can I use? I am looking for samples that can be found outside the laboratory.
01 March 2021 9,101 3 View
We are preparing some experiments based on irradiating cells under different conditions in order to evaluate the effects in terms of DNA damage, genetic expression, etc. As our project is...
01 March 2021 3,355 3 View
I have to amplify a gene and my primers just reached. The Tm for Forward primer is 64.2, and that of reverse primer is 65.5. Can some one suggest how to get the best annealing temperature? Thanks...
01 March 2021 360 7 View
When you use RIA, with a control the unknown sample with antibodies, you bare in mind the binding sites of the antibodies. However you still need to measure labelled antigen (radioactive) and not...
28 February 2021 2,133 3 View
Is there any reason for decrease in fluorescence emission intensity of HSA,BSA when increase the concentration ?
28 February 2021 3,653 4 View
We have always used the 96 welled plate, the 48 welled plate but apparently there is much evidence on the 24 welled plate and above all its benefits.It states it is the same you would use on ELISA...
28 February 2021 1,149 1 View
21 February 2021 3,417 5 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I am designing a small grid connected solar PV power-plant. As the battery's capacity is specified in Ah and demand in kWh. What is the best way to size the battery bank? I have battery price in...
28 February 2021 1,638 3 View
Hello, I have simulated a single battery cell using Thevenin equivalent circuit. For a battery pack, I have a large number of cells connected in series and parallel connections. Is there any way...
28 February 2021 2,116 1 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
Hi, everyone I'm working on a privacy-preserving algorithm that will apply to IoT devices. So, I need to measure the power consumption by implementing this algorithm. Any suggestion, advice,...
25 February 2021 8,749 6 View
Hello everyone, I'm looking for a way to delaminate copper current collector of water-based anodes in Li-ion batteries without damaging the graphite film. I tried different materials such as HNO3...
24 February 2021 3,785 3 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
What are the testing rate for electrodes recommended by ASTM for cochlear implants. I am currently doing the 15mm/min elongatio testing.
22 February 2021 1,515 1 View