I want to functionalize graphene with di ammine.
Hi Muhammad, it depends on the Diamine. What type of Diamine are you going to add onto the graphene surface?
BTW, it's Graphene or Graphene Oxide?
Thank you ALi for your reply.
I want to add o phenylenediamine (OPD) to graphene not on Graphene Oxide.
I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
Actually, I am running cfd simulation for a heat exchanger which has two fluids one hot and other one is cold fluid. there is a solid domain between them, which I removed and instead I have used...
01 March 2021 9,537 2 View
I am simulating Heat Exchanger. I have tried and tested all the methods to resolve this issue from the internet like refining mesh, improving skewness and orthogonal quality ,extending outlet to...
01 March 2021 6,985 3 View
I have to amplify a gene and my primers just reached. The Tm for Forward primer is 64.2, and that of reverse primer is 65.5. Can some one suggest how to get the best annealing temperature? Thanks...
01 March 2021 360 7 View
Should I mesh the solid domain ? or should I use wall thickness? or Shell conduction? for Heat Transfer between two fluids of a Heat Exchanger. what is recommended?
01 March 2021 9,785 3 View
I have a virtual machine. My host Pc specs are not that good thats why i went for virtual servers. so basically my host pc has 8gb of ram with nvidia quadro k2200 4Gb DDR5 GPU ,processor intel...
01 March 2021 8,415 1 View
Is the period to autoclave not enough? The inoculation in a hood and flame and UV and alcohol.
27 February 2021 9,356 3 View
hello. i am junior researcher. I received a comment from a reviewer that he could not find NMR data in my submitted paper. I had included the NMR graph with explanation and formula to calculate...
27 February 2021 734 4 View
I have a sample of treated water sample & asked to obtain ammonia conc. in sample using a machine with 5-25 ppm detection range. However, upon testing with different dilution factors, all...
27 February 2021 8,483 3 View
I am working on TiO2 composite material and the results of XRD have a lot of small/junk peaks and while I apply a smooth filter in Origin then the other characteristics peaks disappear so anyone...
26 February 2021 8,183 3 View
Dear All, I want to quantify carbon deposition on the surface of the CuZnAl catalyst. I have tried thermogravimetric analysis, but I've got weight gain as the active Cu- get oxidised. Does anyone...
01 March 2021 1,907 3 View
I am a student of MS Environmental Engineering and started my research phase. I am working on metal removal ( chromium iii ) by using activated carbon prepared from the agricultural feedstock. So...
01 March 2021 5,475 2 View
In the stabilization of AgNPs are vital in current research interest. However, some of the 2D nano-materials like graphene oxide, MoS2, etc... previously used to stabilize it. But still they shown...
01 March 2021 2,207 3 View
Dear all, I am trying to perform a MD simulation about the interaction between CO2 and a polymer. I create my model, solvate it and perform the NVT and NPT equilibration. Now I am not able to...
26 February 2021 10,014 3 View
Has anyone ever tried to deliver CO2 with a CGA 300 regulator? I know that a CGA 320 regulator is standard for CO2. The issue is that I currently do not have any free CGA 320 regulators. I also...
25 February 2021 3,292 3 View
Respected Professor's i hope you are doing well and happy. i need some information about carbon Nanotubes. before blending the CNT with the matrix the CNT has been introducing in some treatments....
24 February 2021 5,383 5 View
I am trying to reduce graphene oxide by thermally but I have no proper information regarding this. Can any one help me regarding the details about temperature and time for the reduction of...
23 February 2021 4,155 4 View
I need to clean the hydrocarbon contamination on the carbon substrate of TEM grid. However, I heard that substrate could be broken by the powerful plasma. My substrate is pure carbon, with ~3nm,...
23 February 2021 3,262 5 View
I notice that upon washing and air-drying of my RGO/SPCE surface and characterizing again via DPV, the current response towards ferricyanide probe significantly decreases. My worry is that the...
22 February 2021 5,324 3 View