Please name the kit if you used one. I need this for NGS library construction. Thanks
07 August 2014 866 7 View
Where I can get the best workshop to learn how to deal with and analyse NGS Data? Is there something recommended especially in the UK? I need something that start from the beginning by teaching...
02 March 2014 2,574 10 View
Here, I did long-range PCR for ranges between 8-24Kb. I used 0.4% agarose concentration but the PCR stuck to the wells and some of the parts migrated. I am not sure if this is the same products...
02 March 2014 4,098 10 View
I am on the lookout for the Enhanced Yellow Fluorescent Protein (Aequorea victoria) DNA sequence. Does anyone know where I can find it? Thank you in advance
03 March 2021 3,568 1 View
Hello, We would like to increase the yield of our PCR product. We are running a series of PCR reactions that is targeting ~1.1kb sequence. We begin each reaction with ~400pg of template DNA...
02 March 2021 4,029 3 View
So, I have been trying to run a pACYC PCR which will be used later on for a Gibson Assembly. However the PCR is not working. I have already tried gradient PCR and changing extension time; however...
02 March 2021 1,146 2 View
I am going to have 3 different probes in my qPCR work that I am going to do. But I realized that the machine we have in the lab is a Rotor-Gene Q 2plex HRM Platform, saying it has green, yellow,...
01 March 2021 8,544 1 View
We are preparing some experiments based on irradiating cells under different conditions in order to evaluate the effects in terms of DNA damage, genetic expression, etc. As our project is...
01 March 2021 3,355 3 View
To dear Researchers, I was analyzing a series of concentration for estimation of Real-Time PCR efficiency. The concentration was 1:10. I used MS-excel to evaluate Slope. The result of slope was -8...
01 March 2021 8,683 4 View
I am looking at the ATP1A2 (Sodium/Potassium ATPase alpha subunit 2) in two human neuronal cell lines. Expression levels of this protein seems to be almost equal when detected by one antibody....
01 March 2021 3,607 3 View
I performed site directed mutagenesis, transformation, and then I sent out plasmids for Sanger sequencing and found out that there is extension of DNA just before the stop codon. I am not sure...
27 February 2021 547 3 View
Hi, my question is about the heating of thermal cycler machines and I hope some of you had experienced a similar thing previously. There are two thermal cycler machines in the lab(BioRad) and for...
26 February 2021 4,777 4 View
Hi I am a bit confused. They are asking me to find out the volume of DNA required in ul (a total of 30-100 ng for genomic DNA) from the DNA concentration in the nanodrop reading which was 404.8...
26 February 2021 5,029 2 View