Hi Everyone, Am looking for a Methods / Protocols for Electrochemical Biosensors, can some one shed the light on these aspects,since am new to Electrochemical biosensors , my aim is to build a Electrochemical Biosensor to detect microbial pathogens.
These links may help you
http://www.formatex.info/microbiology4/vol1/227-238.pdf
https://books.google.com.my/books?id=2xn1AgAAQBAJ&pg=PA141&lpg=PA141&dq=Electrochemical+Biosensor+to+detect+microbial+pathogens+protocol&source=bl&ots=wqtZmdgyi8&sig=U6UU1dvu7hv3tiKEqMSdiyEme6s&hl=en&sa=X&redir_esc=y#v=onepage&q=Electrochemical%20Biosensor%20to%20detect%20microbial%20pathogens%20protocol&f=false
Chapter Amperometric Biosensor for Pathogenic Bacteria Detection
Article Bacterial Detection & Identification Using Electrochemical Sensors
Article Efficient and Rapid Detection of Salmonella Using Microfluid...
Article Electrochemical Biosensor for the Immediate Detection of Bacteria
Article A brief review on recent developments of electrochemical sen...
Article Electrochemical Biosensor based on Clay for the Immediate De...
Article Development of nanoparticle-based optical sensors for pathog...
Article Real-time in Situ Monitoring of Water Systems Using Electroc...
Article Introducing Schottky barrier into electrochemical response: ...
Article Microbial Identification Using Electrochemical Detection of ...
Thanks Mohamed A. Hammad, This might help.
Thanks Irene
Hi, In most of the DNA biosensor experiments and articles they have used MCH (6-Mercaptohexanol) as a blocking agent, to orient DNA 90o and to remove non-specifically bound from the...
04 May 2019 5,937 1 View
Hi all, Am working on a DNA based biosensor, DNA are thiolated. i reduce thiolated ssDNA by TCEP and dip cast it on a gold nanoparticle coated electrode. I have tried with 500nM ,...
02 March 2019 2,987 2 View
Hi all, How one can calculate the LoD (Limit of detection) and LoB (Limit of Blank) for DNA based biosensor (Label Free). Should one has to take LoB after immobilizing the DNA probe...
31 December 2018 6,223 2 View
Hi all, What are the possibilities of a oxidized nucleobase, getting paired with the complementary base. does it satisfies Chargaff rule ? Can 8-Oxo-Guanine be paired with Cytosine ?
31 December 2018 948 4 View
Hi All, How one can quantify the oligonucleotides for 10 - 100pM range, i had used nanodrop to quantify but ended up with the result same as blank. The oligo's had dispensed in...
11 December 2018 736 2 View
How do they fit the Randle Sevick's Equivalent circuit for multiple data (Nyquist Plot). Since most of the journals shows a single equivalent circuit representing for multiple nyquist plot .
08 September 2018 5,932 5 View
Hi, Am using Electrochemical workstation 660E, Am not able to get X and Y axis values, have tried from rebooting the system to deleting the regedit includes deleting old data. if someone faced...
05 June 2018 5,656 3 View
Hi, Most of the Institutes and Research centers has skilled staff who may be just matriculation passed, as they get experienced they would tackle any troubleshoot or problems they face. Most...
05 June 2018 5,096 3 View
Hi, Is it possible to quantify the amount of DNA that has been immobilized on the gold electrode ?. How to quantify using EIS/ Chronocoulometry or any other methods.
04 May 2018 9,253 3 View
Hi, How difficulty is to remove the AuNp's coated on to the Gold electrode surface, can it be removed completely 100% ? Can one remove the AuNp's by Polishing with Alumina Powder and...
03 April 2018 1,708 3 View
I used eye tracking to examine how participants from two different populations (A and B) react to an image. Participants in population A exhibit larger pupil sizes over time, but they also have...
10 August 2024 3,229 0 View
For example, I perform passivation process before electropolymerization of Py for adhesion to titanium surface. Is a similar or different procedure required for ITO? If necessary, I would be glad...
06 August 2024 3,176 0 View
Hello everyone, I'm encountering an issue with my electrochemical impedance spectroscopy (EIS) measurements and would appreciate some insights. Experimental Setup: Electrodes: Gold interdigitated...
05 August 2024 3,783 2 View
We are planning to establish a microbial laboratory in our research center and are actively seeking the best disinfection methods. If anyone has any recommendations, please let us know. Thank you.
04 August 2024 1,973 1 View
Hi everyone, Recently I have been conducting Dynamic Light scattering experiments in a micellar solution at 5 and gel at 37 degrees of Celsius with latex particles of diameter 190-500 nm. While...
01 August 2024 1,168 4 View
Hello! I have this scale which had 10 items initially. I had to remove items 8 and 10 because they correlated negatively with the scale, and then I removed item 9 because Cronbach's alpha and...
01 August 2024 4,606 7 View
Just bounced on me. Before statistically analysing significant difference, shouldn't we see if data fits normal distribution first? Is 3 replicates enough to testify the hypothesis of normal...
31 July 2024 8,141 13 View
Does anyone know of a module for the JAMOVI software that is capable of generating mean separations using the classic letters based on post hoc results (e.g., Tukey test)? If, as I believe, such...
31 July 2024 3,333 4 View
Hello everyone, I am new to this characterization but watching videos on youtube I have already plotted a Nyquist plot (Z' and -Z'') and already fitted models on my material using Zsim. But now I...
29 July 2024 1,376 0 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View