Hi,
For compensation, we can use single-stained beads in flow cytometry.
For gating control or FMO: can we just mix single-stained beads to get FMO?
It's always best to do your FMO on your cells, you can account for cell autofluorescence levels and get more relevant information about your positive cell populations.
In 84232 add gene plasmid, I am not sure at which site should I clone guide RNA
04 April 2024 8,044 3 View
In addgene 84323, plasmid they have empty gRNA casette. I am not sure where to clin guide RNA of interest. 1. Is it should be between U6 promoter and gRNA casette or 2. In gRNA casette itself?
04 April 2024 8,157 3 View
I have been using the traditional method for characterizing microbial fuel cell where at the end we will obtain power density curve (Power density vs Current) and polarization curve ( Voltage vs...
14 February 2024 957 0 View
I am doing a GC MS analysis of plant volatile compounds. I am observing that the volatile concentration of few compounds decrease in presence of sodalime. Can somebody let me know if soda lime...
09 June 2019 1,712 6 View
I am not clear what is rule behind mirna and mRNA targeting pair,because each mirna target officially 100s of target. In such cases how one will validate legitimate mirna mRNA target. Assays...
21 April 2019 420 4 View
This question is related to soluble film formulation.
04 September 2018 3,223 1 View
PET labelled forward primer for microsatellite detection along with target region, PCR artifact shadow peak of equal intensity observed. artifact since it is not visible on agarose gel.
10 March 2018 2,867 3 View
I want to know how to design primer for primary miRNA QRT PCR
05 March 2018 4,991 6 View
How to draw Scatchard plot, using data of fluorescence intensity and concentrations of ligands and protein only. Please help..
22 January 2018 1,232 4 View
Looking for Chloroform as a solvent for dissolving poorly water soluble drug
04 June 2017 4,552 3 View
I am staining some brain sections stored in cryoprotectant that express a Histone H2B- GFP fusion protein that were generated ~10 years ago. I know I need to enhance signal with an anti-GFP...
07 August 2024 5,338 2 View
To compare positive and negative cell populations in flow cytometry, should I compare unstained cells with antibody stained cells? Or with the isotype control? Most papers show comparison with...
06 August 2024 6,728 6 View
Hi all, I was just wondering if anyone has experience with multiplexing a mouse monoclonal primary and a rat primary. I'm trying to multiplex by incubating them in the same well but was told by a...
06 August 2024 9,710 1 View
Women, on the other hand, can become physically aroused (increased blood flow in the reproductive organs) without becoming psychologically aroused even in the slightest. (Robert Weiss)
05 August 2024 9,537 2 View
Hi guys If anyone is currently working on aging cells, you guys would like to give me some advice. I'm testing against biomarker (SA-beta-Gal), I encountered a false positive in the control group...
02 August 2024 6,735 1 View
We have a lateral flow test on Sartorius 140 NC. The conjugate is gold-monoclonal antibody. Using different control lines (GAM, protein A, protein G) we get a very strong leading edge with reduced...
31 July 2024 4,510 3 View
Hello everyone, I am currently using washed human platelets to stain Annexin V as a procoagulant marker. Additionally, I am staining with PerCP-CD61 to identify platelet cells. So far, I have...
29 July 2024 8,624 1 View
I am running a western on HIV envelope protein. The size is around 50Kda and I am using rat anti-HA for the first stain and a second stain of mouse anti-CA. Primary antibody dilution is 1: 1000...
29 July 2024 6,484 5 View
I cannot confirm cell surface protein expression by flow cytometry even after transfection and antibiotic selection of cells. Does it take long for proteins to express on the cell surface? the...
28 July 2024 3,178 3 View
Hello; I am conducting a CFD study on two-phase flow in a separator, utilizing refrigerant as the working fluid. For this study, I have implemented pressure inlet and pressure outlet boundary...
25 July 2024 2,309 5 View