I have dataset which shows the length of power lines. I need to classify the lines based on the line length. Is there a rule to classify the High voltage (HV) and low voltage (LV) lines based on...
03 March 2021 4,116 4 View
Actually, I am running cfd simulation for a heat exchanger which has two fluids one hot and other one is cold fluid. there is a solid domain between them, which I removed and instead I have used...
01 March 2021 9,537 2 View
I am simulating Heat Exchanger. I have tried and tested all the methods to resolve this issue from the internet like refining mesh, improving skewness and orthogonal quality ,extending outlet to...
01 March 2021 6,985 3 View
I have to amplify a gene and my primers just reached. The Tm for Forward primer is 64.2, and that of reverse primer is 65.5. Can some one suggest how to get the best annealing temperature? Thanks...
01 March 2021 360 7 View
Should I mesh the solid domain ? or should I use wall thickness? or Shell conduction? for Heat Transfer between two fluids of a Heat Exchanger. what is recommended?
01 March 2021 9,785 3 View
I have a virtual machine. My host Pc specs are not that good thats why i went for virtual servers. so basically my host pc has 8gb of ram with nvidia quadro k2200 4Gb DDR5 GPU ,processor intel...
01 March 2021 8,415 1 View
Is the period to autoclave not enough? The inoculation in a hood and flame and UV and alcohol.
27 February 2021 9,356 3 View
hello. i am junior researcher. I received a comment from a reviewer that he could not find NMR data in my submitted paper. I had included the NMR graph with explanation and formula to calculate...
27 February 2021 734 4 View
I have a sample of treated water sample & asked to obtain ammonia conc. in sample using a machine with 5-25 ppm detection range. However, upon testing with different dilution factors, all...
27 February 2021 8,483 3 View
I am working on TiO2 composite material and the results of XRD have a lot of small/junk peaks and while I apply a smooth filter in Origin then the other characteristics peaks disappear so anyone...
26 February 2021 8,183 3 View
I am studying the potential of DCT and FFT coefficients extracted from a signal to classify the different objects that emit the signal. I applied the Shapiro-Wilk to confirm that data was not...
01 March 2021 8,079 2 View
24 February 2021 1,365 3 View
Hello, I have run into an issue that has sparkled a debate at work: is the LLOQ/ULOQ impacted by injection volume under the following circumstances: 1) Same dilution factor of all samples 2)...
23 February 2021 9,159 3 View
Hi all, I have a question regarding calculations using the Pfaffl method. I have 3 groups per experiment: 1 control group (calibrator) and 2 treatment groups with 6 to 7 biological repeats per...
19 February 2021 8,351 2 View
I am aiming to utilise XRPD to quantify a drug excipient within a drug product and have been having a little trouble building the calibration curve to allow for this quantification up until this...
10 February 2021 6,145 3 View
Hello everyone, I did a transformation of E. coli DH10B using pUC18 plasmid. The bacterias did grow on MKL medium with ampicillin but the colonies showed a white/pink colour and the medium was...
08 February 2021 9,720 3 View
Can I know how to apply contourlet transform for signals in MATLAB?Must I first convert 1D signal to 2D image in order to do this method?
01 February 2021 3,735 3 View
Hello everyone. I have been trying to apply radiometric calibration on Sentinel-2 L1C images (bands 2,3,4 and 8), but every time after layerstacking I come across this error: "Calibration...
28 January 2021 7,160 1 View
19 January 2021 602 2 View
18 January 2021 7,257 2 View