in medical electodes uses the ag / agcl ... why we use cl ion specifically ??
You can find your answer in detail in 5th chapter of this book:
"Medical Instrumentation Application and Design" (James Webster)
Hi everyone I need a file with a dirty and clean potato image
04 August 2024 7,199 4 View
Hi I am working on data driven model of the microgrid, for that, i need the reliable datasets for the identification of MG data driven Model. Thanks
02 August 2024 5,748 4 View
I have a Simulink model that connected a main utility (AC-grid) with a three-phase load changing from 20kW to 100kW in 5 seconds and I don't know how to build this load in Simulink. Please your...
14 July 2024 8,892 3 View
The question us regarding catalase activity check of bacterial strains. I saw an article in which it was written that we can use 30%hydrogen peroxide for catalase activity but in our laboratories...
12 July 2024 8,794 2 View
how i can calculate mathematically COD concentration if i add 1gr from glucose to 1 L distilled water
08 July 2024 9,104 2 View
Sometimes there are differences in citations on Google Scholar compared to citations in Researchgate- What are the main reasons?
05 June 2024 2,222 4 View
I am using a rectangle Ni foam electrode area: (0.5 * 1 = 0.5 cm2) for OER and applying material to the area (0.5 * 0.5 = 0.25 cm2) and depositing the same area in the solution. Now, do I need to...
29 May 2024 1,454 5 View
I have submitted two manuscripts to IJOC for about 9 months ago. For both of them, their first response email (immediate response email received on the submission date) stated that "it typically...
20 May 2024 1,897 3 View
Hi I am trying to implement the MPC with the SINDYc model, But, the SINDY model identifies the equation in differential equation form, and MPC needs a State space model, can anyone guide, me on...
29 April 2024 2,614 0 View
I am running SDS-Page western blot using 10% acrylamide gels. However, my samples are not migrating more than 55 kDa. The bands are not defined. I am using 4x Laemmli buffer with LDS from Biorad....
22 April 2024 7,469 11 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
I am writing to request a correction regarding the affiliation of one of my co-authors, Donald Ho. Currently, the author's profile incorrectly lists an affiliation with The Hong Kong Polytechnic...
28 July 2024 6,824 0 View
I'm very interested in biotechnology and medical research and I'd like to meet a professional here and talk about it together
28 July 2024 3,798 4 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View
I am trying to drop cast 2D Materials on Glassy Carbon Electrode for Cyclic voltametry and EIS purpose. What would be best binders to use?
23 July 2024 5,776 2 View