the image show cv of ball milled graphite sample at different scan rates,it shows quasi rectangle shape,does this graph show any good features of capacitance and conductivity?
Dear Vishnu Ps,
Please check the potential window from -0.8 V to 0.3 V, and see the CV curves.
Better try to scan in the positive potential window.
Hello, Can anyone provide me with the absorption coefficient of methane gas at 7.7 um? Any reference?
06 August 2024 980 5 View
Hello everyone! I am currently exploring the performance of large models in understanding knowledge in specific domains, and attempting to construct a knowledge framework similar to what...
05 August 2024 5,729 2 View
Regarding a model for simulating battery charge and discharge, what do you consider to be high fidelity? What is the acceptable percentage of error (regardless of the metric)? Could you suggest...
03 August 2024 5,358 0 View
need to open an account to upload my published papers
01 August 2024 9,255 1 View
All plants are green but some of these plants becomes yellow. I did not found any reason. Please help me to find out the real problem.
01 August 2024 589 4 View
I am using a Bruker 600M solid-state NMR spectrometer with a Micro 2.5 microimaging system. The test sample is a tube of 1M LiCl aqueous solution, and the nucleus detected is 1H. I am trying to...
01 August 2024 9,227 1 View
Hello. Thanks for your consideration to see my question. Recently, I conducted XPS anaylsis of g-CN that is prepared from thermal polycondensation of DCDA, so-called conventional bulk-g-CN,...
30 July 2024 9,824 2 View
N=6 Comparing pre and post test likert scale responses. Participants are mix of practicing & preservice teachers.
30 July 2024 7,233 4 View
Hello, I'm trying to measure the conductivity of semiconductor films but since I don't have a commercial four point probe set up I would like to build one on my own in my lab. I have generators,...
30 July 2024 906 2 View
Can an analytical method's limit of quantification (LOQ) be outside its linear dynamic range, or is it always required to be within it? Please provide a thorough explanation supported by verified...
29 July 2024 7,198 9 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
I imagine the battery drives the graphite into a carbocation, then chloride is oxidized to donate the electron to the carbocation, but what pushes the lost electrons of chloride to be shared...
03 August 2024 5,384 0 View
I got comment on my FTIR data figure from a reviewer. The reviewer said "FTIR data in Figure should be repeated. there is no bassline." I made Y off set comparison graph of FTIR on OriginLab. Can...
03 August 2024 6,070 3 View
I am in search of a modified Hummer's method, which can be used to synthesis graphene oxide within 6-8 hours. As I am a student it is not allowed for us to work after 5 in the laboratory. So I am...
01 August 2024 8,368 2 View
I have used Prussian blue nanoparticles as a redox couple. The PBNPs have been made using only one salt precursor. Also, during scan rate studies, a small oxidation peak can be consistently found...
31 July 2024 9,697 0 View
The starting material is a finely ground powder. Some particles contain more graphene than others.
30 July 2024 3,978 2 View
The entropy measured of molecular graphs plays a crucial rule. The network structures in some cases are very lengthy calculations to handle. Some author avoid to construct table where as most...
30 July 2024 3,126 0 View
Hello everyone, I am new to this characterization but watching videos on youtube I have already plotted a Nyquist plot (Z' and -Z'') and already fitted models on my material using Zsim. But now I...
29 July 2024 1,376 0 View
Here, I have attached the UPS graph. I'm trying to calculate the DOS/DOVS from the UPS.
29 July 2024 4,971 1 View