Hi the software highscore is preventing me from the changing the anode type from Co to Cu the was it should be , the option under customize document wavelength is grayed out!
Thank you
How can we differentiate between calcite, dolomite, siderite, magnesite and ankerite minerals in carbonatite rocks in thin section under optical microscope?
07 August 2024 2,131 3 View
Hi, we have measured tryptic peptides using both DDA and DIA method on QExactive. In DDA replicates i saw unusual intensity drops occurring at the same sections of chromatograms in DDA replicates...
07 August 2024 3,216 4 View
Dear fellow researchers, I am currently working on a paper where I need to provide a reliable reference that defines and distinguishes between 3D mesh models and 3D city models. Although I am...
06 August 2024 9,984 2 View
Hello, Can anyone provide me with the absorption coefficient of methane gas at 7.7 um? Any reference?
06 August 2024 978 5 View
I am conducting a qualitative study that uses interviews to investigate the perceptions of teachers about a particular leadership practice and I am focusing on 3 schools which have a total number...
01 August 2024 8,456 10 View
Hello I am conducting a microstructural analysis of a soil treated with lime. The following sem images are of the untreated s1 and treated soil s3. The untreated soil contains quartz calcite...
01 August 2024 572 0 View
HI there, I've came across several articles discuss about random audit an Non random to tax evasion or compliance. Most of the articles is relating about effect of audit (random or non random)...
31 July 2024 5,309 7 View
Can we patent a process flow diagram developed using a process simulator but no actual cases is carried out? For example consider a process for certain product manufacture where a new process flow...
31 July 2024 780 1 View
How can we calculate the percentage of configuration interaction (CI) in the UV output data of the Gaussian program? for example: Excited State 17: Singlet-A 5.1359 eV 241.41 nm...
28 July 2024 9,165 2 View
Please, what is the memory consumption of the Matlab function quad tree decomposition procedure [S = qtdecomp(I)] with respect to the input set I?
27 July 2024 5,455 2 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,628 1 View
I attempted to make a privately uploaded text public but a window appeared that said an error occurred. There was no explanation provided as to why there was an error or what might be done to...
05 August 2024 8,025 7 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,622 3 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 941 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,536 3 View
It has been documented that apoptotic cells themselves can induce phosphorylation of serine 139 on H2AX (γH2AX) due to DNA fragmentation during apoptosis (doi: 10.1074/jbc.275.13.9390). As γH2AX...
28 July 2024 7,982 2 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View
I am trying to drop cast 2D Materials on Glassy Carbon Electrode for Cyclic voltametry and EIS purpose. What would be best binders to use?
23 July 2024 5,776 2 View