I want to know the difference between Li-ion battery (which is in Half cell configuration, suppose, LiCoO2 as cathode and Li metal foil as reference electrode) and Li metal battery?
When explaining substitution models, the substitutions are expressed as Q matrix. Why is the sum of the elements in a row zero?
28 February 2021 3,864 3 View
I am looking forward to remove excess of salt form my metal based porphyrin and trying DSC-18 columns for the same, can someone suggest me how how can one decide the polarity of the solvent to...
01 February 2021 9,076 1 View
I have generated two antibodies against two peptide fractions of a protein in the rabbit. I want to use these two antibodies (Ab-1 and Ab-2) in indirect sandwich ELISA for the detection of...
11 January 2021 1,754 4 View
I have categorized the disturbance basically on movement of people and vehicle in into 3 categories. Disturbed, close to highway and movement of people from dusk to dawn. Intermediately...
30 December 2020 8,806 4 View
I have checked annealing temperature through gradient PCR. I have checked my primer in NCBI. I have checked PCR reagents concentration. Please suggest me anyone thanks
12 December 2020 1,969 2 View
If I am drilling through bars of different material(ex: iron, steel etc.) of the same thickness and under the same conditions of drill operations(feed rate and rpm), how will the torque and thrust...
06 November 2020 4,498 3 View
I have generated an antibody against an antigen. Now, I want to use the developed antibody in the detection of the unknown sample. So, I want to coat the plasma sample as antigen. How that can be...
26 October 2020 2,259 7 View
As we know that the global temperatures are increasing due to climate change which could affect the thermal needs of the crops. I want to make geospatial maps and analysis for heat requirements of...
28 September 2020 8,286 2 View
I am simulating a NW based MSM Photodetector with Si/ CdTe/InAs NWs (modeled in SDE)with moderate doping, and have assumed a constant generation rate in the the Physics Section of SDEVICE 1....
03 September 2020 5,971 10 View
I tried to submit research projects on climate change and Remote sensing to many agencies but could not get it though? Is there any easily available agencies who support the research in the subject.
16 August 2020 4,000 18 View
I am using a Sutter electrode holder for my patch clamp experiments, but I'm having trouble keeping positive pressure inside my electrode due to a leak out of the back of the holder. I have added...
02 March 2021 5,829 1 View
I want to do RF sputtering of ITO on glass substrate using magnetron sputtering. what thickness do i need to make it good conductive layer to use it for PSC. Moreover, whats about thickness of...
01 March 2021 395 3 View
I am designing a small grid connected solar PV power-plant. As the battery's capacity is specified in Ah and demand in kWh. What is the best way to size the battery bank? I have battery price in...
28 February 2021 1,638 3 View
Hello, I have simulated a single battery cell using Thevenin equivalent circuit. For a battery pack, I have a large number of cells connected in series and parallel connections. Is there any way...
28 February 2021 2,116 1 View
I am conducting anodic electrodeposition of MnO2 onto a stainless steel substrate, using a platinum strip as a counter electrode. This is done galvanostatically, with the current held between 5...
27 February 2021 1,829 3 View
During performing CV of a GCE or modified GCE, we rise the potential in the first half of the cycle and reduce it in reverse half. During the first half, what is the nature of charge on GCE or...
25 February 2021 7,994 3 View
Hi, everyone I'm working on a privacy-preserving algorithm that will apply to IoT devices. So, I need to measure the power consumption by implementing this algorithm. Any suggestion, advice,...
25 February 2021 8,749 6 View
Hello everyone, I'm looking for a way to delaminate copper current collector of water-based anodes in Li-ion batteries without damaging the graphite film. I tried different materials such as HNO3...
24 February 2021 3,785 3 View
I am trying to characterize an electrochromic system. The system uses ITO electrodes on glass, WO3 as the electrochromic film, and NiO as the ion storage layer. When I deposit NiO and WO3 and...
23 February 2021 9,592 2 View
What are the testing rate for electrodes recommended by ASTM for cochlear implants. I am currently doing the 15mm/min elongatio testing.
22 February 2021 1,515 1 View