Hi,
as attached files I have just tried to find pore size of an SEM image but in output files there is no any unit, so kindly tell me the units of calculated values? I didn't change anything in "set scale" option of imageJ, I used default.
The answer will be in pixels unless you set scale using a known length in your image.
Ok Sir, I will follow this. can we convert pixels into required units (micrometer or nanometer)?
Thank you so much Sir, I will follow it.
I have done ORR LSV (attached file) at different RPM (400-2000) in 0.1M KOH electrolyte (PH=13) using RDE. My teacher said that it is wrong due to limiting current density. Kindly give me your...
08 September 2019 1,841 2 View
I used Image j but I didn't get correct result, is there another way to calculate particle size?
05 June 2019 9,018 3 View
Please suggest me a correct method of dilution of solutions to convert ppm to ppb. Let suppose I have 0.05 mg/ml solution, it has 50 ppm and I want to convert into different ppb solutions like 50,...
04 May 2019 9,461 1 View
Hi, I have used American Mineralogist crystal database and downloaded .cif files and then used VESTA software to simulate XRD pattern and also have jcpdf number, I want to match with my own XRD...
04 May 2019 1,936 4 View
Is there any literature or trilaterals?
04 May 2019 3,459 6 View
Hi, everyone, I needed JCPDS files of Pt, Cu, PtCu & Cu3Pt, if anyone have then please share with me, I will be highly thankful. File numbers are as follows: PtCu = JCPDS 48-1549 Pt = JCPDS...
04 May 2019 2,260 4 View
I did BET for my catalyst (PtCu Nano particles) when I got result, I saw this error (given in attached figure), as BET Surface area is too low, what does "fail'' mean? is it incomplete analysis or...
03 April 2019 7,184 10 View
For the conversion of the applied potential vs Hg/HgO electrode potential vs reversible hydrogen electrode (RHE) using the Nernst equation as follows: ERHE = EHg/HgO + 0.059 × pH +...
01 February 2019 5,405 3 View
01 February 2019 5,119 12 View
I have collected a LSV data by taking Hg/HgO as the reference electrode. But I want to convert this one to RHE. Please suggest me the required conversion equation. 0.1M KOH was taken as the...
01 February 2019 7,122 4 View
I have virus (viral hemorrhagic septicemia virus) in suspension and the experiment will not involve cells. What level of TCID50 is preferred?
11 August 2024 3,115 1 View
I am developing a predictive model for a water supply network that involves 20 influencing points. However, I only have historical data for 10 out of these 20 points. I would like to know how to...
10 August 2024 4,005 2 View
Usually, additive manufacturing techniques like SEBM, SLS, and SLM are used for interconnected porous lattice structure generation with sizes of >100–200 micrometers. Can the Fused Deposition...
09 August 2024 7,892 0 View
I need to model an anisotropic material in which the Poisson's ratio ν_12 ≠ ν_21 and so on. Therefore, the elastic compliance matrix wouldn't be a symmetric one. In ANSYS APDL, for TB,ANEL...
09 August 2024 5,048 2 View
I am trying to simulate vehicular loading on an orthotopic steel deck bridge section in ABAQUS software. The red arrow mark in the attached figure indicates the direction in which the vehicle will...
08 August 2024 718 0 View
If we map as a continuous motion an ionising electron (beginning its journey at n=1) in an H atom, a specific hyperbolic spiral appears (see animation). When we solve this spiral formula, we find...
07 August 2024 5,342 2 View
Hello dear colleagues, We have prepared a manuscript on NiTi-based alloys and are seeking a second opinion on our current TEM results. If you are a Ph.D. holder with experience in TEM and have...
07 August 2024 9,563 0 View
Dear fellow researchers, I am currently working on a paper where I need to provide a reliable reference that defines and distinguishes between 3D mesh models and 3D city models. Although I am...
06 August 2024 9,986 2 View
After immunohistochemistry of previously fixed in PFA and EtOH and then frozen 20 μm sections of zebrafish brain, DAPI staining is very weak (right) compared to the same sections stained without...
05 August 2024 9,637 2 View
I am working on Abaqus/Explicit(Quasistatic ) for the deformation of the auxetic structure model. Please explain how the plastic input value should be considered from the true stress-strain curve...
05 August 2024 453 3 View