I have collected a LSV data by taking Hg/HgO as the reference electrode. But I want to convert this one to RHE. Please suggest me the required conversion equation. 0.1M KOH was taken as the supporting electrolyte.
Hello Anand Parkash
You should find the following resource useful:
http://www.consultrsr.net/resources/ref/refpotls.htm
Jules
Thank you so much Jules Lloyd Hammond.
Dear Anand,
I think pH of the supporting electrolyte should be taken into consideration before converting your values to RHE scale. You can use the formula:
E(RHE)=E (Hg/HgO) + E0 (Hg/HgO) + 0.0591pH
The following article may be helpful for you.
Article Elucidation of the structural and charge separation properti...
I have two questions:
1. what is the exact value of E0 (Hg/HgO) in 0.1M KOH?
2. How we can calculate mass loading on GC?
I have done ORR LSV (attached file) at different RPM (400-2000) in 0.1M KOH electrolyte (PH=13) using RDE. My teacher said that it is wrong due to limiting current density. Kindly give me your...
08 September 2019 1,841 2 View
I used Image j but I didn't get correct result, is there another way to calculate particle size?
05 June 2019 9,018 3 View
Hi, I have used American Mineralogist crystal database and downloaded .cif files and then used VESTA software to simulate XRD pattern and also have jcpdf number, I want to match with my own XRD...
04 May 2019 1,936 4 View
Please suggest me a correct method of dilution of solutions to convert ppm to ppb. Let suppose I have 0.05 mg/ml solution, it has 50 ppm and I want to convert into different ppb solutions like 50,...
04 May 2019 9,462 1 View
Is there any literature or trilaterals?
04 May 2019 3,460 6 View
Hi, everyone, I needed JCPDS files of Pt, Cu, PtCu & Cu3Pt, if anyone have then please share with me, I will be highly thankful. File numbers are as follows: PtCu = JCPDS 48-1549 Pt = JCPDS...
04 May 2019 2,260 4 View
I did BET for my catalyst (PtCu Nano particles) when I got result, I saw this error (given in attached figure), as BET Surface area is too low, what does "fail'' mean? is it incomplete analysis or...
03 April 2019 7,184 10 View
For the conversion of the applied potential vs Hg/HgO electrode potential vs reversible hydrogen electrode (RHE) using the Nernst equation as follows: ERHE = EHg/HgO + 0.059 × pH +...
01 February 2019 5,405 3 View
01 February 2019 5,119 12 View
Hi, It would be a great help if I can get the cif. file or the X/Y data of ZIF-8 and MOF-74. Thanks a lot in advance.
11 December 2018 8,381 0 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,628 1 View
Hello. I am working on ROS production of two systems: system A is cerium oxide and hydrogen peroxide, system B is cerium oxide nanoparticle, hydrogen peroxide and potassium bromide. I did some...
04 August 2024 5,973 3 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,623 3 View
I heard an explanation about something being a better proton acceptor or lone pair donor but that doesn't make sense. I couldn't explain in in terms of acid-base theory. The hand-waving way I saw...
03 August 2024 9,918 0 View
I'm trying to calculate the tolerance factors of the hydride perovskite and the value calculated by me and the reported values are contradictory. Need more clarity in using the correct ionic radii...
01 August 2024 2,614 1 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Hello Everyone! I am trying to create a metal hydride system where I am trying to create a temperature control with the emphasis on measuring the concentration of the hydrogen with the hydrogen...
29 July 2024 7,577 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
For people today, the enigma of the size of the proton still remains enigmatic. However, being myself a researcher in new physical theory which makes it possible to extend the different standard...
28 July 2024 7,823 1 View