Initially I had succesfully cloned 526bp, 425bp and a 256bp target cDNA into a pGEMT easy vector systems (Promega). Sequencing results were found to be positive on BLAST search. Then, in oder to proceed for full length cloning, I had tried RACE cloning using CLONTECH SMARTer RACE cDNA kit and Advantage 2 PCR kit (Clontech). 5' RACE PCR amplication resulted in a single band of 1100bp, while 3' RACE PCR of 1450bp when run on 1.5% agarose gel. Everything then on went fine, clones were screened by blue white screening method. Colony PCR was positve with both GSPs and T7 and SP6 universal primers. Plasmids were isolated and plasmid PCR with GSPs were positive showing single band at appropriate place. But sequencing results defied all results and didnt show any closer matching. I am stuck with this part (extension of 526bp target gene) very badly. I have tried both classical cloning with new primers and RACE (5' and 3') with both old and new primer sets but everytime met with failures. If anyone here can give valuable suggestions, I will be able to go a step further.