There exist many kinds of H2O2 sensing electrodes. Please could you tell me the advantages and disadvantages of the conventional H2O2 sensors?
The surface structure of the 3D printed Ti alloys samples can be regulated by the diameter of the metal microspheres, the power of the 3D laser beam, the scanning rate and other process...
02 December 2017 2,902 3 View
06 July 2016 3,068 0 View
Electrochemical applications such as electrochemical biosensor ( HRP/anatase-TiO2/Ti substrate).
05 June 2015 7,437 1 View
02 June 2015 4,161 1 View
In some reported works for biosensors, they study the cathodic peak current vs various scan rates. The linear relationship indicating that the electrochemical kinetics of electrode biosensor was a...
04 May 2015 8,737 6 View
I have H2O2 biosensor (Nafion/HRP/TiO2 film/ITO substrate), and i want to measure and evaluate the direct electron transfer between the enzyme and the electrode.
08 September 2014 6,542 7 View
I have an H2O2 biosensor electrode and I want to optimize the experiment, such as the pH of the PBS and applied voltage of the sensor. So how can I do it? And should the PBS solution stir during...
16 August 2014 9,534 8 View
07 August 2014 9,094 9 View
Does selecting the initial voltage in the AMperometric I-t curve depend on the CV plot?
04 May 2014 4,219 2 View
I'm preparing H2O2 biosensor by growing nanodot on substrat, but the sensitivity always very low, is it because of the HRP, or Nafion or PBS? or because of the Initial potential of the...
06 July 2013 3,299 2 View
I tried four trials of the same Copper Phosphides sample in Alkaline medium ( 0.5M KOH) with Hg/HgO reference electrode and Pt as counter electrode. I used 0.001 V/s scan rate for first three...
10 August 2024 3,629 1 View
My name is Apurva Saoji. I am a Ph.D scholar in Computer engineering in India. I am looking for international expert in reviewing my PhD thesis, "Competitive Optimization Techniques to Minimize...
07 August 2024 4,600 2 View
I have been using paraffin, but the deposited ZnO still detach from electrode. What is the best binder to modify graphite paste electrode with ZnO nanoparticles?
03 August 2024 4,624 3 View
Hello I want a suitable journal in the field of remote sensing and machine learning to be judged quickly. Thank you for your guidance Thanks
01 August 2024 1,799 4 View
My screen printed electrode CV is given here. For Nerstean one electron reaction the delta E value should be close to 57 mV and ration of Ic/Ia should be close to 1. I did CV of my screen printed...
30 July 2024 4,671 3 View
We are working on biopolymeric hydrogels. Our system is highly viscous and sticky, and the gel formed are high in strength. We are unable to use pH electrode and pH strip. Please suggest an easy...
30 July 2024 942 2 View
Here, I have used Ag/AgCl as reference electrode and 0.5M KOH.
29 July 2024 4,538 3 View
need of sensor details or sensor development for this question.
28 July 2024 4,539 3 View
While I am doing HER, I noticed that nyquist plots of Electrochemical Impedance Spectroscopy (EIS) is not complete. Will it affect for the Linear Sweep Voltametry (LSV) data? However, I can found...
26 July 2024 7,542 4 View
As shown in the figures, there are several abnormal charge/discharge curves.Each of them may have different problems. I am curious why these situations appeared differently?There are a lot of...
24 July 2024 6,930 1 View