I need to prepare a synthetic medium. In the literature, they used di-potassium hydrogen orthophosphate trihydrate. In my lab, di-potassium hydrogen orthophosphate ( anhydrous ) is available. can I use it? TIA
This should not affect bacterial growth so long as you account for the different in molecular mass.
i.e. 1 gram of the trihydrate is the same as 0.763 gram of the anhydrous.
i am doing dark fermentation with thermophilic bacteria and nanoparticle as supplementation.
23 August 2023 2,996 1 View
my plan is to attach HAp nanoparticle on solid material.
29 December 2022 6,200 3 View
There have many processes to measure the BOD of wastewater. i want to know the easiest procedure
28 July 2022 4,828 4 View
1. I need to immobilize microbes, how can I understand that hydroxyapatite chemical is antibacterial?
18 July 2022 5,785 3 View
from a mixed culture , I want to isolate single one.
15 June 2022 3,088 0 View
Hi! So i attempted to understand a novel protein behavior towards heat application by analyzing its secondary structure change. I subjected the protein to a thermal denaturation analysis using...
06 August 2024 1,989 3 View
Hello. I am working on ROS production of two systems: system A is cerium oxide and hydrogen peroxide, system B is cerium oxide nanoparticle, hydrogen peroxide and potassium bromide. I did some...
04 August 2024 5,974 3 View
I heard an explanation about something being a better proton acceptor or lone pair donor but that doesn't make sense. I couldn't explain in in terms of acid-base theory. The hand-waving way I saw...
03 August 2024 9,918 0 View
I'm trying to calculate the tolerance factors of the hydride perovskite and the value calculated by me and the reported values are contradictory. Need more clarity in using the correct ionic radii...
01 August 2024 2,614 1 View
Hello Everyone! I am trying to create a metal hydride system where I am trying to create a temperature control with the emphasis on measuring the concentration of the hydrogen with the hydrogen...
29 July 2024 7,577 2 View
I want to preserve the sample leaves for the LM study of the stomata and conidia analysis. Whether 2.5% glutaraldehyde in 0.05 M phosphate buffer with pH 7 can be applied for preservation.
29 July 2024 8,560 0 View
For people today, the enigma of the size of the proton still remains enigmatic. However, being myself a researcher in new physical theory which makes it possible to extend the different standard...
28 July 2024 7,823 1 View
In general, when performing a Tafel analysis for corrosion resistance measurements, a line voltage scan is performed from say -250 to +250 mV vs. OCV at low scan speed around 0.125 mV/s. However,...
25 July 2024 7,982 3 View
I have tried to saturate ferritic steel with hydrogen using the electrolytic method and H2SO4. However, the effect was very poor even after 3 days of "saturation". Can anybody help in choosing a...
24 July 2024 4,393 2 View
I am new to research. The boiling point of triethyl amine (NEt3) is 89 degrees centigrade. I am skeptical that when I will let the hydrogen escape which is getting generated in situ, I will also...
21 July 2024 7,284 4 View